Showing 1045-1056 of 2042 item(s)
Showing 1045-1056 of 2042 item(s)

Active filters

PCB-034W10

  • Protection class IP 68
  • Shielded four-wire Teflon cable
  • Length 3 meters
  • 4-pin connector to three BNC connectors

    PCB-3741F1230G

    • MEMS accelerometer
    • Suitable for measuring static accelerations
    • Measuring range ± 30 g pk (± 294.2m / s²)
    • Sensitivity (± 3%) 90 mV / g (9.17mV / (m / s²))
    • Frequency range (± 5%) 0… 1,500 Hz
    • Supply voltage 5… 32 V DC
    • Integrated connection cable, length 3 meters,
      ending on stripped and tinned ends

      "On-Line" vibration monitor A3900 II

      • measures vibration velocity (10 Hz... 1 kHz),
      • measures vibration Acceleration (10 Hz... 1 kHz),
      • measures RMS (RMS) and peak (peak),
      • integrated sensor power supply, ICP®
      • adjustable 4.. 20 mA current loop (active or passive),.
      • programmable limit value (alert, alarm).
      • RS-232 serial interface

        TMS-2100E11

        • Modal Shaker
        • Force 440 N,.
        • Frequency range 0... 5,400 Hz,
        • Stroke 25.4 mm

          PCB-356A61

          • Triaxial ICP® miniature vibration sensor,
          • With built-in low-pass filter,.
          • Measuring range 500 g
          • Sensitivity 10 mV / g,.
          • Frequency range 2... 4,000 Hz,
          • Weight 4 grams.
          • Integrated cable, length 1.5 m,
            ending on 4-pin female connector.
          • Including extension cable, length 1.5 m,
            ending on three BNC plugs

            PCB-356A43

            • Triaxial ICP® miniature vibration sensor,
            • With TEDS 1.0,
            • Measuring range 500 g,
            • Sensitivity 10 mV / g,
            • Frequency range 0.4... 10,000 Hz,
            • Dimensions 4.2 grams,
            • 4-pin female connector on the side

              PCB-176M03

              • Pressure sensor with charge output for detecting combustion instability in turbines,
              • With ATEX / CSA approval,
              • Continuous use temperature up to 530 ° C,
              • With UHT-12™ sensor element,
                (no popcorn noise),
              • Measurement range 1.4 bar,
              • Sensitivity 247 pC/bar,
              • Frequency range up to 10,000 Hz,
              • Integrated hardline cable,
                ending on 7/16-27-connector

                PCB-(M)202B

                • ICP® force-load washer, 
                • Measuring range 1 kN, 
                • Sensitivity 4991 mV / kN, 
                • Frequency range 0.005 ... 65.000 Hz, 
                • 10-32 connector on the side

                  PCB-350B44

                  • Triaxial ICP® shock acceleration sensor
                  • Ground Isolated
                  • With electrical and mechanical filter
                    (-3 dB at 21,000 Hz)
                  • Measuring range 5,000 g
                  • Sensitivity 1.0 mV / g
                  • Frequency range 0.4 ... 10,000 Hz
                  • Integrated connection cable, length 1.5 meters,
                    ending on 4-pin connection socket
                  • Including extension cable, length 1.5 meters,
                    ending on three BNC plugs

                    PCB-034W20

                    • Protection class IP 68
                    • Shielded four-wire Teflon cable
                    • Length 6 meters
                    • 4-pin connector to three BNC connectors

                      PCB-3711F1150G

                      • MEMS accelerometer
                      • Suitable for measuring static accelerations
                      • Measuring range ± 50 g pk (± 490m / s²)
                      • Sensitivity (± 3%) 27 mV / g (2.8mV / (m / s²))
                      • Typical frequency range (± 5%) 0… 1,500 Hz
                      • Supply voltage 5… 32 V DC
                      • 4-pin connection socket on the side

                        PCB-3741F1250G

                        • MEMS accelerometer
                        • Suitable for measuring static accelerations
                        • Measuring range ± 50 g pk (± 490m / s²)
                        • Sensitivity (± 3%) 54 mV / g (5.5mV / (m / s²))
                        • Frequency range (± 5%) 0… 1,500 Hz
                        • Supply voltage 5… 32 V DC
                        • Integrated connection cable, length 3 meters,
                          ending on stripped and tinned ends