Low frequencies

Low frequencies

To monitor low-speed machines, such as fans in cooling towers, or to measure at bridges and structures, sensors with good low-frequency characteristics are needed. PCB Piezotronics offers industrial ICP® vibration sensors for measurements up to 0.1 Hz (Model PCB-601M51).

Showing 1-12 of 21 item(s)
Showing 1-12 of 21 item(s)

Active filters

PCB-(M)625B00

  • Industrial ICP® vibration sensor,
  • With through hole,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 0.2 … 10,500 Hz,
  • Frequency response calibration,
  • 2-pin female connector on the side
    • PCB-(M)625B01

    • Industrial ICP® vibration sensor,
    • With through hole,
    • Measurement range 50 g,
    • Sensitivity 100 mV/g,
    • Frequency range 0.2 … 10,500 Hz,
    • Frequency response calibration,
    • 2-pin female connector on the side
      • PCB-(M)625B02

      • Industrial ICP® vibration sensor,
      • With through hole,
      • Measuring range 10 g,
      • Sensitivity500 mV / g,
      • Frequency range 0.2 … 6,000 Hz,
      • Frequency response calibration,
      • 2-pin female connector on the side
        • PCB-(M)625B11

        • Industrial ICP® vibration sensor,
        • With through hole,
        • Measurement range 50 g,
        • Sensitivity 100 mV/g,
        • Frequency range 0.2 … 10,500 Hz,
        • Frequency response calibration,
        • Integrated cable, length 3 m,
          ending on cut end
          • PCB-(M)625B12

          • Industrial ICP® vibration sensor,
          • With through hole,
          • Measuring range 10 g,
          • Sensitivity500 mV / g,
          • Frequency range 0.2 … 6,000 Hz,
          • Frequency response calibration,
          • Integrated cable, length 3 m,
            ending on cut end
            • PCB-(M)625B60

            • Industrial ICP® vibration sensor,
            • With through hole,
            • Measuring range 500 g
            • Sensitivity 10 mV / g,
            • Frequency range 0.2 … 10,500 Hz,
            • Frequency response calibration,
            • Integrated armored cable, length 3 m,
              ending on cut end
              • PCB-(M)625B61

              • Industrial ICP® vibration sensor,
              • With through hole,
              • Measurement range 50 g,
              • Sensitivity 100 mV/g,
              • Frequency range 0.2 … 10,500 Hz,
              • Frequency response calibration,
              • Integrated armored cable, length 3 m,
                ending on cut end
                • PCB-(M)625B62

                • Industrial ICP® vibration sensor,
                • With through hole,
                • Measuring range 10 g,
                • Sensitivity500 mV / g,
                • Frequency range 0.2 … 6,000 Hz,
                • Frequency response calibration,
                • Integrated armored cable, length 3 m,
                  ending on cut end
                  • PCB-(M)626A04

                  • Industrial ICP® vibration sensor for seismic measurements,
                  • Measuring range 0.5 g,
                  • Sensitivity 10,000 mV / g,
                  • Frequency range 0.04 … 500 Hz,
                  • Frequency response calibration,
                  • 2-pin female connector above
                    • PCB-(M)626B01

                    • Industrial ICP® vibration sensor,
                    • Measurement range 50 g,
                    • Sensitivity 100 mV/g,
                    • Frequency range 0.2 … 10,000 Hz,
                    • Frequency response calibration,
                    • 2-pin female connector above
                      • PCB-(M)601A02

                      • Industrial ICP® vibration sensor,
                      • Measuring range 10 g,
                      • Sensitivity500 mV / g,
                      • Frequency range 0.17 … 10,000 Hz,
                      • One-point calibration at 100 Hz,
                      • 2-pin female connector above
                        • PCB-(M)626B02

                        • Industrial ICP® vibration sensor,
                        • Measuring range 10 g,
                        • Sensitivity500 mV / g,
                        • Frequency range 0.2 … 6,000 Hz,
                        • Frequency response calibration,
                        • 2-pin female connector above