PCB-350B42
- Triaxial ICP® shock acceleration sensor
- Mass insulated
- With electrical and mechanical filter
(-3 dB at 17,000 Hz) - Measuring range 50,000 g
- Sensitivity 0.1 mV / g
- Frequency range 4 ... 10,000 Hz
- Integrated connection cable, length 1.5 meters,
ending on a 4-pin connection socket - Including extension cable, length 1.5 meters,
ending on three BNC plugs
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Sensitivity (± 30%) | 0,1 mV/g | 0,01 mV/(m/s²) | |
Measuring range | ± 50,000 g pk | ±440.000 m/s²pk | |
Frequency range (± 1 dB) | 4 … 10.000 Hz | ||
Resonance frequency | >50.000 Hz | ||
Corner frequency of the electrical filter (3 dB) | 17.000 Hz | [1][2] | |
Resonance frequency of the mechanical filter | 35.000 Hz | [1][3] | |
Broadband resolution (1 ... 10,000 Hz) | 0,5 gRMS | 4,9 m/s²RMS | [1] |
Linearitätsfehler | ≤2,5 % | ||
Lateral acceleration sensitivity | ≤7 % | ||
Conditions of use | |||
Overload limit (shock) | ± 150,000 g pk | ±1.471.500 m/s²pk | |
Temperature range (operation) | -10 … 150 °F | -23 … 66 °C | |
Temperature range (storage) | -40 … 200 °F | -40 … 93 °C | |
Stretch sensitivity (base area) | 0.002 g / ml | 0.02 (m / s²) / ε | [1] |
Technical characteristics | |||
Supply voltage | 20 … 30 VDC | ||
Constant current supply | 2… 20 mA | ||
Output impedance | ≤200 Ω | ||
Bias voltage | 8 … 14 VDC | ||
Discharge time constant | 0,1 s | [1] | |
Settling time (to bias voltage ± 10%) | <1 s | ||
Electrical insulation (base) | >100 MΩ | ||
Physical characteristics | |||
Sensor element | Ceramics | ||
Geometry of the sensor element | Scherprinzip | ||
Housing material | Titan | ||
seal | Hermetically sealed | ||
Size - height | 1,02 in | 26,0 mm | |
Size - length | 1,02 in | 26,0 mm | |
Size - width | 1,02 in | 26,0 mm | |
Mass (without cable) | 0.95 oz | 27 grams | [1] |
Cable outlet | Laterally | ||
Cable termination | 4-pin socket (1/4 "-28) | ||
Cable length | 5,0 ft | 1,52 m | |
Cable type | Type 034, shielded 4-wire cable | ||
Attachment | Through holes |
Hints | |||
---|---|---|---|
[1] | Typically | ||
[2] | Second order low pass filter | ||
[3] | The amplitude is increased by 9 dB in the range of the resonance frequency. | ||
[4] | Shaker test at 100 Hz | ||
[5] | Details: siehe PCB Declaration of Conformance PS023 |
included supply | ||
---|---|---|
034G05 | Shielded 4-wire cable, length 1.5 meters, 4-pin connector on three BNC connectors | (1) |
100-16040-40 | Mounting screw M6 x 1.0 | (2) |
100-6774-10 | Mounting screw 1/4 "-28 | (2) |
100-8994-40 | Grease | (1) |
ACS-14T | Hopkinson bar calibration for shock transducers | (1) |
ACS-22T | Frequency response for triaxial transducers, traceable to NIST (100 Hz up to the upper ± 1dB point | (1) |