Piezoelectric pressure sensors-

Piezoelectric Pressure Sensor

.

Showing 1-12 of 107 item(s)
Showing 1-12 of 107 item(s)

Active filters

PCB-137B27

  • Measurement Range: 500 psi (3447 kPa)
  • Sensitivity: (±15%) 10 mV/psi (1.45 mV/kPa)
  • Resonant Frequency: >=400 kHz
  • Electrical Connector: 4-Pin
  • Weight: 16.1 oz (456 gm)

    PCB-137B28

    • Measurement Range: 1000 psi (6895 kPa)
    • Sensitivity: (±15%) 1 mV/psi (.145 mV/kPa)
    • Resonant Frequency: >=400 kHz
    • Electrical Connector: 4-Pin
    • Weight: 16.1 oz (456 gm)

      PCB-176M09

      • Measurement Range: 20 psi (1.4 bar)
      • Sensitivity: (±20%) 17 pC/psi (247 pC/bar)
      • Sensing Element: UHT-12™
      • Temperature Range: -94 to 986 °F (-70 to 530 °C)
      • Electrical Connector: 7/16-27 2-Pin
      • Weight: 8.3 oz (235 gm)

        PCB-176A02

        • Pressure sensor with charge output for detecting combustion instability in turbines,
        • With ATEX / CSA approval,
        • Continuous use temperature up to 650 ° C,
        • With UHT-12™ sensor element,
          (no popcorn noise),
        • Measurement range 50 bar,
        • Sensitivity 87 pC/bar,
        • Frequency range up to 20,000 Hz,
        • Integrated hardline cable, length 3 m,
          ending on 7/16-27-connector

          PCB-176A03

          • Pressure sensor with charge output for detecting combustion instability in turbines,
          • With ATEX / CSA approval,
          • Continuous use temperature up to 650 ° C,
          • With UHT-12™ sensor element,
            (no popcorn noise),
          • Measuring range 20 bar,
          • Sensitivity 232 pC/bar,
          • Frequency range up to 10,000 Hz,
          • Integrated hardline cable, length 3 m,
            ending on 7/16-27-connector

            PCB-176A04

            • Pressure sensor with charge output for detecting combustion instability in turbines,
            • Continuous use temperature up to 350 ° C,
            • With UHT-12™ sensor element,
              (no popcorn noise),
            • Measuring range 20 bar,
            • Sensitivity 2.25 pC/kPa,
            • Frequency range up to 10,000 Hz,
            • 7/16-27-socket

              PCB-176A05

              • Pressure sensor with charge output for detecting combustion instability in turbines,
              • With ATEX / CSA approval,
              • Continuous use temperature up to 520 ° C,
              • With UHT-12™ sensor element,
                (no popcorn noise),
              • Measuring range 5 bar,
              • Sensitivity 750 pC/bar,
              • Frequency range up to 8,000 Hz,
              • Integrated hardline cable, length 3 m,
                ending on 7/16-27-connector

                PCB-176M03

                • Pressure sensor with charge output for detecting combustion instability in turbines,
                • With ATEX / CSA approval,
                • Continuous use temperature up to 530 ° C,
                • With UHT-12™ sensor element,
                  (no popcorn noise),
                • Measurement range 1.4 bar,
                • Sensitivity 247 pC/bar,
                • Frequency range up to 10,000 Hz,
                • Integrated hardline cable,
                  ending on 7/16-27-connector

                  PCB-176M07

                  • Pressure sensor with charge output for detecting combustion instability in turbines,
                  • With ATEX / CSA approval,
                  • Continuous use temperature up to 530 ° C,
                  • With UHT-12™ sensor element,
                    (no popcorn noise)
                  • Measurement range 1.4 bar,
                  • Sensitivity 247 pC/bar,
                  • Frequency range up to 1500 Hz,
                  • Integrated hardline cable,
                    ending on 7/16-27-connector

                    PCB-176M12

                    • Pressure sensor with charge output for detecting combustion instability in turbines,
                    • With ATEX / CSA approval,
                    • Continuous use temperature up to 530 ° C,
                    • With UHT-12™ sensor element,
                      (no popcorn noise),
                    • Measurement range 1.4 bar,
                    • Sensitivity 247 pC/bar,
                    • Frequency range up to 1500 Hz,
                    • Integrated hardline cable,
                      ending on 7/16-27-connector

                      PCB-132B38

                      • Miniature-ICP® pressure sensor
                      • Measuring range 345 kPa
                      • Sensitivity 20.3 mV / kPa
                      • Frequency range 11... 1,000 kHz
                      • Integrated cable, length 3 m,
                        ending on open ends

                        PCB-106B

                        • Sub-miniature ICP® pressure sensor with stainless steel diaphragm
                        • Measuring range 690 kPa
                        • Sensitivity 7.3 mV / kPa
                        • Lower limit frequency 0.5 Hz
                        • Integrated connection cable