Strength and strain sensors-

Force and Strain Sensors

.

Showing 1-12 of 90 item(s)
Showing 1-12 of 90 item(s)

Active filters

PCB-740M04

  • ICP® strain sensor, 
  • Measuring range 900 με, 
  • Sensitivity 5 mV / με, 
  • Frequency range 0.5 ... 100,000 Hz, 
  • Integrated connection cable, length 3 meters,
    ending on 10-32 plug

PCB-740M06

  • ICP® strain sensor, 
  • Measuring range 900 με, 
  • Sensitivity 2 pC / με, 
  • Frequency range 0.5 ... 100,000 Hz, 
  • Integrated connection cable, length 3 meters,
    ending on 10-32 plug

PCB-JM240A03

  • ICP® strain sensor, 
  • Measuring range 300 με, 
  • Sensitivity 10 mV / με, 
  • Lower limit frequency 0.004 Hz, 
  • 10-32 connector on the side, 
  • Masseisolierung

PCB-261M09

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 0,111 kN, 
  • Measuring range (X and Y axis) 0.044 kN, 
  • Sensitivity (Z axis) 22.5 mV / N, 
  • Sensitivity (X and Y axis) 112 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.01 ... 90,000 Hz, 
  • 4-pin connection socket on the side

PCB-260M29

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 0.445 kN, 
  • Measuring range (X and Y axis) 0.444 kN, 
  • Sensitivity (Z-axis) 5.60 mV / N, 
  • Sensitivity (X and Y axis) 11.25 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.001 ... 90,000 Hz, 
  • 4-pin connection socket on the side

PCB-260M36

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 45 N, 
  • Measuring range (X and Y axis) 45 N, 
  • Sensitivity (Z-axis) 110 mV / N, 
  • Sensitivity (X and Y axis) 110 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.001 ... 90,000 Hz, 
  • 4-pin connection socket on the side

PCB-260M21

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 4.45 kN, 
  • Measuring range (X and Y axis) 0.044 kN, 
  • Sensitivity (Z axis) 22.5 mV / N, 
  • Sensitivity (X and Y axis) 122 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.01 ... 90,000 Hz, 
  • 4-pin connection socket on the side

PCB-(M)202B

  • ICP® force-load washer, 
  • Measuring range 1 kN, 
  • Sensitivity 4991 mV / kN, 
  • Frequency range 0.005 ... 65.000 Hz, 
  • 10-32 connector on the side

PCB-M1403-02B

  • Load cell for static measurements,
  • Measuring range 2,500 N,
  • Nominal 1 mV / V,
  • Anschlusskonnektor PC04E-10-6 p side illustration

    shows load cell load base PCB M084A100 < br(separat erhältlich)

    PCB-M1631-06C

  • S type load cell,
  • Measuring range 20 kN,
  • Nominal 2 mV / V,
  • Integrated cable, length 3 m,
    ending on open ends

    PCB-M1631-04C

  • S type load cell,
  • Measuring range≥ 10 kΩ,
  • Nominal 2 mV / V,
  • Integrated cable, length 3 m,
    ending on open ends

    PCB-M1631-03C

  • S type load cell,
  • Measuring range 5,000 N,
  • Nominal 2 mV / V,
  • Integrated cable, length 3 m,
    ending on open ends