Showing 1333-1344 of 2042 item(s)
Showing 1333-1344 of 2042 item(s)

Active filters

PCB-378A07

  • 1/2 "-ICP® precision microphone for free-field applications,
  • Suitable for Infraschallmessungen,
  • Combination of microphone capsule PCB 377A07 and preamp PCB-426E01,
  • Sensitivity 5.8 mV / PA,
  • Dynamic range > 134 dB,
  • Frequency range 0.1 … 20,000 Hz,
  • BNC connector,
  • As system calibrated
    • PCB-(M)601A92

    • Industrial ICP® vibration sensor,
    • Measuring range 10 g,
    • Sensitivity500 mV / g,
    • Frequency range 0.17 … 10,000 Hz,
    • One-point calibration at 100 Hz,
    • M12 connection socket top
      • PCB-(M)604B31

      • Triaxial industrial ICP® vibration sensor,
      • With through hole,
      • Measurement range 50 g,
      • Sensitivity 100 mV/g,
      • Frequency range 0.5 … 5,000 Hz,
      • One-point calibration at 100 Hz,
      • 4-pin bayonet connector on the side
        • PCB-(M)621C40

          • Industrial ICP®-miniature vibration sensor,
          • Measuring range 500 g
          • Sensitivity 10 mV / g,
          • Frequency range 1.6 … 30,000 Hz,
          • Frequency response calibration,
          • 5-44 female connector above

            PCB-(M)625B11

          • Industrial ICP® vibration sensor,
          • With through hole,
          • Measurement range 50 g,
          • Sensitivity 100 mV/g,
          • Frequency range 0.2 … 10,500 Hz,
          • Frequency response calibration,
          • Integrated cable, length 3 m,
            ending on cut end
            • PCB-(M)628F01

            • Industrial ICP® vibration sensor,
            • Measurement range 50 g,
            • Sensitivity 100 mV/g,
            • Frequency range 0.33 … 12.000 Hz,
            • Frequency response calibration,
            • 2-pin female connector above
              • PCB-EX(M)607A11

              • Industrial ICP® vibration sensor,
              • With ATEX / CSA approval,
              • Measurement range 50 g,
              • Sensitivity 100 mV/g,
              • Frequency range 0.5 … 10,000 Hz,
              • One-point calibration at 100 Hz,
              • Free ausrichtbares integrated cable, length 3 m,
                ending on cut end
                • PCB-426A11

                • ICP® preamplifiers for 1/2 "-microphones,
                • Slide switch-configurable,
                • Output signal high-pass filtered, unfiltered and A weighted,
                • Gain 0 dB or 20 dB,
                • Frequency range 5 … 125,000 Hz,
                • Incl. TEDS memory chip
                  • PCB-377A07

                  • Prepolarized 1/2 "precision microphone for free-field applications,
                  • Suitable for Infraschallmessungen,
                  • Sensitivity 50 mV / PA,
                  • Dynamic range > 145 dB,
                  • Frequency range 0.07 … 20,000 Hz
                    • PCB-378A12

                    • 1/4 "-ICP® precision microphone for pressure applications,
                    • Combination of microphone capsule PCB 377A12 and preamp PCB-426 B 03,
                    • Sensitivity 0.25 mV / PA,
                    • Dynamic range > 177 dB,
                    • Frequency range 5 … 20,000 Hz,
                    • 10-32 socket
                    • As system calibrated
                      • PCB-(M)601M51

                      • Industrial ICP® vibration sensor,
                      • Measuring range 10 g,
                      • Sensitivity500 mV / g,
                      • Frequency range 0.1 … 10,000 Hz,
                      • One-point calibration at 100 Hz,
                      • 2-pin female connector above
                        • PCB-(M)604B61

                        • Triaxial industrial ICP® vibration sensor,
                        • With through hole,
                        • Measurement range 50 g,
                        • Sensitivity 100 mV/g,
                        • Frequency range 0.5 … 5,000 Hz,
                        • One-point calibration at 100 Hz,
                        • Integrated armored cable, length 3 m,
                          ending on cut end