PCB-(M)607A61
basic data | |||||
sensitivity (±15%) | 100 mV/g | 10.2 mV/(m/s²) | [6] | ||
measuring range | ±50 g | ±490 m / s² | |||
Frequency range (± 3 dB) | 30 … 600,000 cpm | 0.5 … 10,000 Hz | |||
resonance frequency | 1,500 kcpm | 25,000 Hz | [1] | ||
Wide band resolution | 350 µg | 3.434 µm / s ² | [1] | ||
linearity | ≤1% | [3] | |||
Lateral acceleration sensitivity | ≤ 7% | ||||
Conditions of use | |||||
Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |||
Temperature range | -65 … 250 ° F | -54 … 121 ° C | |||
protection class | IP67 | ||||
technical characteristics | |||||
Settling time (on bias voltage ± 1%) | ≤ 2 s | ||||
discharging charging time constant | ≥0.3 s | ||||
[5] | two-core cable with stainless steel reinforcement | ||||
[6] | conversion factor 1 g = 9.81 m/s² | ||||
[7] | Assembly requires Allen key 1/8 "(for inch mounting bolts) or 3 mm (for metric mounting bolts). | ||||
[8] | of the mounting bolts must be tightened with a higher torque than the hex nut, so that the sensor can easily be removed. | ||||
[9] | details: see PCBs Declaration of conformance PS023 and PS060 | ||||
Accessories | |||||
080A156 | mounting bolts 1/2 "-20 1/4" 28 | -1 | |||
ICS-2 | single point calibration at 100 Hz (traceable to NIST) | -1 | |||
(M) metric mounting | |||||
equipment | |||||
M080A159A | mounting bolts 1/2 "20 M6 x 1 | -1 | |||
(TO) temperature output | |||||
temperature range | 36 & Emmap; 250 ° F | 2 … 121 ° C | |||
transcription factor | 5.56 mV / ° F (zero point at 32 °F) | 10 mV / ° C | |||
electrical connection | Integrated armoured cable | ||||
connections (red wire) | acceleration output | ||||
(black wire) pin assigNment | Mass | ||||
Pin assigNment (white wire) | temperature output | ||||
(EX) with ATEX approval | |||||
approved for explosive atmosphere eras | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 | ||||
approval for use in potentially explosive atmospheres | EEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 3 G | ||||
Approval for use in potentially explosive atmospheres | EEx nL IIC T4,-40 ° C≤Ta≤121 ° C, II 1 G | ||||
approval for explosionsgef ährdete atmospheres | CL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I | ||||
approval for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 |