Strength and strain sensors-

Force and Strain Sensors

.

Showing 37-48 of 90 item(s)
Showing 37-48 of 90 item(s)

Active filters

PCB-(M)213B

  • Force measuring washer with charge output,
  • Measuring range 89 kN,
  • Sensitivity 4.05 pC/N,.
  • Upper cutoff frequency?60.000 Hz.
  • 10-32 socket side

    PCB-(M)231B

  • Force measuring element with charge output,
  • Range 4.448 … 22,240 N,
  • Sensitivity 4.05 pC/N,
  • Upper frequency limit 15,000 Hz,
  • 10-32 female connector on the side
    • PCB-201B05

    • ICP® power measurement washer,
    • Measuring range 22 kN,
    • Sensitivity 225 mV / kN,
    • Frequency range 0.0003 … 90,000 Hz,
    • 10-32 female connector on the side
      • PCB-(M)214B

      • Force measuring washer with charge output,
      • Measuring range 178 kN,
      • Sensitivity 4.05 pC/N,.
      • Upper frequency limit 55,000 Hz,.
      • 10-32 socket side
        • PCB-(M)234B

          • Force measuring element with charge output,
          • Range 35.6 … 111 kN,
          • Sensitivity 4.05 pC/N,
          • Upper frequency limit 8,000 Hz,
          • 10-32 female connector on the side

            PCB-(M)202B

          • ICP® power measurement washer,
          • Measuring range 44.5 kN,
          • Sensitivity 112 mV / kN,
          • Frequency range 0.0003 … 60,000 Hz,
          • 10-32 female connector on the side
            • PCB-(M)215B

            • Force measuring washer with charge output,
            • Measuring range 267 kN,
            • Sensitivity 4.05 pC/N,.
            • Upper frequency limit 50,000 Hz,.
            • 10-32 socket side
              • PCB-(M)260A01

              • Triaxial ICP® power sensor,
              • Measuring range (Z axis) 4.45 kN,
              • Measuring range (X - and Y-axes) 2.22 kN,
              • Sensitivity (Z-axis) 0.56 mV / N,
              • Sensitivity (X - and Y-axes) 2.25 mV / N,
              • Frequency range (Z axis) 0.01 … 90,000 Hz,
              • Frequency range (X - and Y-axes) 0.001 … 90,000 Hz,
              • 4-pin female connector on the side
                • PCB-(M)203B

                • ICP® power measurement washer,
                • Measuring range 89 kN,
                • Sensitivity 56 mV / kN,
                • Frequency range 0.0003 … 60,000 Hz,
                • 10-32 female connector on the side
                  • PCB-(M)216B

                  • Force measuring washer with charge output,
                  • Measuring range 356 kN
                  • Sensitivity 4.05 pC/N,.
                  • Upper frequency limit 40,000 Hz,.
                  • 10-32 socket side
                    • PCB-(M)260A02

                    • Triaxial ICP® power sensor,
                    • Measuring range (Z axis) 4.45 kN,
                    • Measuring range (X - and Y-axes) 4.45 kN,
                    • Sensitivity (Z-axis) 0.56 mV / N,
                    • Sensitivity (X - and Y-axes) 1.12 mV / N,
                    • Frequency range (Z axis) 0.01 … 90,000 Hz,
                    • Frequency range (X - and Y-axes) 0.001 … 90,000 Hz,
                    • 4-pin female connector on the side
                      • PCB-(M)204C

                      • ICP® power measurement washer,
                      • Measuring range 178 kN,
                      • Sensitivity 27 mV / kN,
                      • Frequency range 0.0003 … 55,000 Hz,
                      • 10-32 female connector on the side