PCB-(M)260A02
zoom_out_map

PCB-(M)260A02

  • Triaxial ICP® power sensor,
  • Measuring range (Z axis) 4.45 kN,
  • Measuring range (X - and Y-axes) 4.45 kN,
  • Sensitivity (Z-axis) 0.56 mV / N,
  • Sensitivity (X - and Y-axes) 1.12 mV / N,
  • Frequency range (Z axis) 0.01 … 90,000 Hz,
  • Frequency range (X - and Y-axes) 0.001 … 90,000 Hz,
  • 4-pin female connector on the side
  •  

    basic data
    sensitivity (Z axis) (±20%) 2.5 mV / N lb/0.56 mV / N [2] [3]
     
    sensitivity (X - and Y-axes) (±20%) 5 mV / lb 1.12 mV / N [2] [3]
     
    measuring range (Z axis) 1,000 lb 4.45 kN  
     
    measuring range (X - and Y-axes) 1,000 lb 4.45 kN  
     
    Maximum power (Z axis) 1,320 lb 5.87 kN  
     
    maximum force (X - and Y-axes) 1,000 lb 4.45 kN  
     
    maximum torque ( Z-Achse) 40 ft-lb 54,23 Nm  
     
    maximum moment (X - and Y-axes) 70 ft-lb 94,91 Nm  
     
    wide band resolution (Z axis) 0.006 lb RMS 0.027 N RMS [1]
     
    Wide band resolution (X - and Y-axes) 0.006 lb RMS 0.027 N RMS [1]
     
    Upper cut-off frequency 90,000 Hz    
     
    lower limiting frequency(Z axis) (-5%) 0.01 Hz    
     
    Lower limiting frequency (X - and Y-axes) (-5%) 0.001 Hz    
     
    linearity ≤ 1% FS   [4]
     
    Crosstalk (between X - and Y-axis) ±3%    
     
    crosstalk (between X and y axis and Z axis) ≤5%    
    Conditions of use
    temperature range -65 … 250 ° F -54 … 121 ° C  
    technical characteristics
    maximum output signal (Z axis) ± 2.5 V DC    
     
    maximum output signal (X - and Y-axes) ±5 V DC    
     
    Discharging charging time constant (Z axis) ≥ 50 s    
     
    discharging charging time constant (X - and Y-axes) ≥ 500 s    
     
    Supply voltage (all axes) 20 … 30 V DC    
     
    constant power supply (all axes) 2 … 20 mA Connection 4-Pin    
     
    connection position side    
    notes
    [1] typically    
     
    [2] when using the recommended preload. The sensitivities can depending on the preload to ±5% change.    
     
    [3] the specified sensitivities are valid only when using the supplied bolt.    
     
    [4] zero-based balancing line, determined using the method of least squares    
     
    [5] the preload should be at least ten times the be on the X - and Y-axis of used operating range.    
     
    [6] details: see PCBs Declaration of conformance PS023    
    equipment
    081A74 pre load bolt (for which Models 260A02, 260A12, and 260A32) -1  
     
    082 M 12 washer (for models 260A02, 260A12, and 260A32) -1  
     
    083A13 Einbauh ülse (for the models 260A02, 260A12, and 260A32) -1  
    (W) waterproof cable
    cable exit side    
    (M)Metric mounting
    equipment      
     
    M081A74 mounting bolts -1  
    PCB-(M)260A02

    Specific References

    Download

    260A02_drawing.PDF

    Technical drawing

    Download (113.92k)

    260A02_manual.PDF

    Operating instructions

    Download (983.97k)

    260A02_specs.PDF

    Technical data sheet

    Download (83.36k)