Strength and strain sensors-

Force and Strain Sensors

.

Showing 49-60 of 90 item(s)
Showing 49-60 of 90 item(s)

Active filters

PCB-200B05

  • ICP® sensor for power measurement,
  • Measuring range 22.2 kN,
  • Sensitivity 225 mV / kN,
  • Frequency range 0.0003 … 75,000 Hz,
  • 10-32 female connector on the side
    • PCB-208C03

    • Universally applicable ICP® power sensor,
    • Measuring range 2.224 N,
    • Sensitivity 2.25 mV / N,
    • Frequency range 0.0003 … 36,000 Hz,
    • 10-32 female connector on the side
      • PCB-(M)222B

      • ICP® force measuring element,
      • Range 11,1 … 26.7 kN,
      • Sensitivity 202 mV / kN,
      • Frequency range 0.0003 … 12.000 Hz,
      • 10-32 female connector on the side
        • PCB-(M)261A03

        • Triaxial ICP® power measurement element
        • Measuring range (Z axis) 44.5 kN,
        • Measuring range (X - and Y-axes) 17.8 kN,
        • Sensitivity (Z-axis) 0.06 mV / N,
        • Sensitivity (X - and Y-axes) 0.28 mV / N,
        • Frequency range (Z axis) 0.01 … 10,000 Hz,
        • Frequency range (X - and Y-axes) 0.001 … 10,000 Hz,
        • 4-pin female connector on the side
          • PCB-200C20

          • ICP® sensor for power measurement,
          • Measuring range 89 kN,
          • Sensitivity 56.2 mV / kN,
          • Frequency range 0.0003 … 40,000 Hz,
          • 10-32 female connector on the side
            • PCB-208C04

            • Universally applicable ICP® power sensor,
            • Range 2,224 … 4.448 N,
            • Sensitivity 1.12 mV / N,
            • Frequency range 0.01 … 36,000 Hz,
            • 10-32 female connector on the side
              • PCB-(M)223B

              • ICP® force measuring element,
              • Range 17.8 … 53 kN,
              • Sensitivity 94 mV / kN,
              • Frequency range 0.0003 … 10,000 Hz,
              • 10-32 female connector on the side
                • PCB-200C50

                  • ICP® sensor for power measurement,
                  • Measuring range 222 kN,
                  • Sensitivity 22.5 mV / kN,.
                  • Frequency range 0.0003... 30,000 Hz,
                  • 10-32 socket side

                    PCB-208C05

                  • Universally applicable ICP® power sensor,
                  • Range 2,224 … 22,240 N,
                  • Sensitivity 225 mV / kN,
                  • Frequency range 0.01 … 36,000 Hz,
                  • 10-32 female connector on the side
                    • PCB-(M)224C

                    • ICP® force measuring element,
                    • Range 35.6 … 129 kN,
                    • Sensitivity 45 mV / kN,
                    • Frequency range 0.0003 … 8,000 Hz,
                    • 10-32 female connector on the side
                      • PCB-201B01

                      • ICP® power measurement washer,
                      • Measuring range 44.5 N,
                      • Sensitivity 112 mV / N,
                      • Frequency range 0.01 … 90,000 Hz,
                      • 10-32 female connector on the side
                        • PCB-(M)209C01

                        • Miniature-ICP® power sensor,
                        • Range 4.5 … 9.8 N,
                        • Sensitivity 495 mV / N,
                        • Frequency range 0.5 … 30,000 Hz,
                        • 10-32 female connector on the side