PCB-(M)260A11
    zoom_out_map

      PCB-(M)260A11

    • Triaxial force sensor with charge output,
    • Measuring range (Z axis) 4.45 kN,
    • Measuring range (X - and Y-axes) 2.22 kN,
    • Sensitivity (Z-axis) 3.4 pC/N,.
    • Sensitivity (X - and Y-axes) 7.2 pC/N,.
    • Upper frequency limit 90,000 Hz,.
    • Three 10-32 connectors on the side
    •  

      basic data
      sensitivity (Z axis) (±15%)15 pC/lb3.37 pC/N[1]
       
      sensitivity (X - and Y-axes) (±15%)32 pC/lb7.19 pC/N[1]
       
      measuring range (Z axis)1,000 lb4.45 kN 
       
      measuring range (X - and Y-axes)500 lb2.22 kN 
       
      Maximum power (Z axis)1,320 lb5.87 kN 
       
      Maximum force (X - and Y-axes)660 lb2,94 kN 
       
      maximum moment (Z-axis)14 ft-lb18.98 Nm 
       
      maximum Moment (X - and Y-axes)13 ft-lb17,63 Nm 
       
      upper cut-off frequency90,000 Hz  
       
      linearity≤ 1% FS [2]
       
      Crosstalk (between X - and Y-axis)±3%  
       
      crosstalk (between X and y axis and Z axis)≤5%  
      Conditions of use
      Temperature range-100 … 350 ° F-73 … 177 ° C 
      Technical characteristics
      capacity (all axes)18 pF [3]
       
      insulation resistance (all axes)≥1,000,000 MΩ  
       
      Output polarity (towards the marks)negative  
      physical properties
      preload? 5,000 lb? 22.25 kN[4]
       
      Stiffness (Z axis)10 lb/µin1.75 kN/µm[3]
       
      rigidity (X - and Y-axes)4 lb/µin0.7 kN/µm[3]
       
      Size - height0,390 in9.90 mm 
       
      size - length0,950 in24.1 mm 
       
      size -. Wide0,950 in24.1 mm 
       
      size - inner diameter0,319 in8.10 mm 
       
      size - diameter of the Messoberflä Che0,680 in17,27 mm 
       
      ground0,868 oz24,59 grams 
       
      housing materialstainless steel  
       
      Sealedsealedclose  
       
      electrical connectionthree 10-32 coaxial jacks  
       
      connection positionside  
      Notes
      [1]when using the recommended preload. The sensitivities can depending on the preload to ±5% change.  
       
      [2]zero-based balancing line, determined using the method of least squares  
       
      [3]typically  
       
      [4]should be at least ten times of the operating range used on the X - and Y-axes preload.  
      Equipment
      081A70mounting bolts-1 
       
      082 B 02washer-1 
       
      083A10mounting sleeve-1 
      (W) waterproof cable
      cable exitside  
      (M) metric mounting
      Accessories   
       
      M081A70mounting bolts-1 
      PCB-(M)260A11

      Specific References

      Download

      260A11_drawing.PDF

      Technical drawing

      Download (333.85k)

      260A11_manual.PDF

      Operating instructions

      Download (2.06M)

      260A11_specs.PDF

      Technical data sheet

      Download (149.6k)