PCB-(M)224C
basic data | ||||
sensitivity (±15%) | 0.20 mV / lb | 44,96 mV / kN | ||
measuring range (pressure) | 25,000 lb | 111.2 kN | ||
Measuring range (traction) | 8,000 lb | 35,59 kN | ||
maximum permissible static load (force) | 29,000 lb | 129.00 kN | ||
Maximum permissible static load (traction) | 10,000 lb | 44.48 kN | ||
wide band resolution | 0.60 lb RMS | 2.67 N RMS | [1] | |
Lower limiting frequency (-5%) | 0.0003 Hz | [2] | ||
upper frequency limit | 8,000 Hz | [4] | ||
linearity error | ≤ 1.5% FS | [3] | ||
conditions | ||||
temperature range | -65 … 250 ° F | -54 … 121 ° C | ||
Temperature coefficient of sensitivity | ≤ 0.03 %/°F | ≤ 0,054 %/°C | ||
technical properties | ||||
discharge charge time constant (at room temperature) | ≥ 2,000 s | close | ||
electrical connection | 10-32-coaxial socket | |||
connection position | side | |||
Mounting thread | 5/8-18 female | |||
notes | ||||
[1] | typically | |||
[2] | on the basis of the Calculated discharge charge time constant | |||
[3] | zero-based balancing line, determined using the method of least squares | |||
[4] | Accepted value determined on the basis of solid state Dynamics calculations | |||
(M) metric mounting | ||||
(S) negative output polarity | ||||
(W) waterproof cable connection | ||||
electrical connection | sealed cable connection | |||
cable outlet | Side |