PCB-(M)223B
    zoom_out_map

      PCB-(M)223B

    • ICP® force measuring element,
    • Range 17.8 … 53 kN,
    • Sensitivity 94 mV / kN,
    • Frequency range 0.0003 … 10,000 Hz,
    • 10-32 female connector on the side
    • of
      basic data
      sensitivity (±15%)mV 0.42 / lb94,42 mV / kN
      measuring range (pressure)12,000 lb53,38 kN
      Measuring range (traction)4,000 lb17.79 kN
      maximum permissible static load (force)10,000 lb44.48 kN
      maximum static force (traction)4,500 lb20,02 kN
      wide band resolution0.40 lb RMS1.78 N RMS[1]
      Lower limiting frequency (-5%)0.0003 Hz[2]
      upper cut-off frequency10,000 Hz[4]
      linearity error≤ 1% FS[3]
      conditions
      temperature range-65 … 250 ° F-54 … 121 ° C
      temperature coefficient Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C
      technical properties
      discharge charge time constant (at room temperature)≥ 2,000 s
      Notes
      [1]typically
      [2]calculated using the discharge load time constant
      [3]zero-based balancing line, determined using the method of least squares
      [4]suppose value determined on the basis of solid state Dynamics calculations
      [5]details: see PCBs Declaration of conformance PS023
      (M) metric mounting
      (S) negative output polarity
      (W) waterproof cable connection
      electrical connectionsealed cable connection
      cable exitside
      PCB-(M)223B

      Specific References

      Download

      223B_drawing.PDF

      Technical drawing

      Download (66.08k)

      223B_manual.PDF

      Operating instructions

      Download (919.79k)

      223B_specs.PDF

      Technical data sheet

      Download (71.49k)