PCB-(M)223B
zoom_out_map

PCB-(M)223B

  • ICP® force measuring element,
  • Range 17.8 … 53 kN,
  • Sensitivity 94 mV / kN,
  • Frequency range 0.0003 … 10,000 Hz,
  • 10-32 female connector on the side
  • of
    basic data
    sensitivity (±15%) mV 0.42 / lb 94,42 mV / kN
    measuring range (pressure) 12,000 lb 53,38 kN
    Measuring range (traction) 4,000 lb 17.79 kN
    maximum permissible static load (force) 10,000 lb 44.48 kN
    maximum static force (traction) 4,500 lb 20,02 kN
    wide band resolution 0.40 lb RMS 1.78 N RMS [1]
    Lower limiting frequency (-5%) 0.0003 Hz [2]
    upper cut-off frequency10,000 Hz [4]
    linearity error ≤ 1% FS [3]
    conditions
    temperature range -65 … 250 ° F -54 … 121 ° C
    temperature coefficient Temperature coefficient of sensitivity ≤ 0.03 %/°F ≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature) ≥ 2,000 s
    Notes
    [1] typically
    [2] calculated using the discharge load time constant
    [3] zero-based balancing line, determined using the method of least squares
    [4] suppose value determined on the basis of solid state Dynamics calculations
    [5] details: see PCBs Declaration of conformance PS023
    (M) metric mounting
    (S) negative output polarity
    (W) waterproof cable connection
    electrical connection sealed cable connection
    cable exit side
    PCB-(M)223B

    Specific References

    Download

    223B_drawing.PDF

    Technical drawing

    Download (66.08k)

    223B_manual.PDF

    Operating instructions

    Download (919.79k)

    223B_specs.PDF

    Technical data sheet

    Download (71.49k)