PCB-M1403-01A

  • Load cell for static measurements,
  • Measuring range 1,250 N,
  • Nominal 1 mV / V,
  • Anschlusskonnektor PT02E-10-6 p side illustration

    shows load cell load base PCB M084A100 < br(separat erhältlich)
    • PCB-M1403-02A

    • Load cell for static measurements,
    • Measuring range 2,500 N,
    • Nominal 1 mV / V,
    • Anschlusskonnektor PT02E-10-6 p side illustration

      shows load cell load base PCB M084A100 < br(separat erhältlich)
      • PCB-M1403-03A

      • Load cell for static measurements,
      • Measuring range 5,000 N,
      • Nominal 1 mV / V,
      • Anschlusskonnektor PT02E-10-6 p side illustration

        shows load cell load base PCB M084A100 < br(separat erhältlich)
        • PCB-M1630-03C

        • S type load cell,
        • Measuring range 200 g,
        • Nominal 2 mV / V,
        • Integrated cable, length 3 m,
          ending on open ends
          • PCB-M1630-04C

          • S type load cell,
          • Measuring range 500 N,
          • Nominal 2 mV / V,
          • Integrated cable, length 3 m,
            ending on open ends
            • PCB-M1630-06C

            • S type load cell,
            • Measuring range 1000 N,
            • Nominal 2 mV / V,
            • Integrated cable, length 3 m,
              ending on open ends
              • PCB-M1631-01C

              • S type load cell,
              • Measuring range 2,500 N,
              • Nominal 2 mV / V,
              • Integrated cable, length 3 m,
                ending on open ends
                • PCB-M1631-03C

                • S type load cell,
                • Measuring range 5,000 N,
                • Nominal 2 mV / V,
                • Integrated cable, length 3 m,
                  ending on open ends
                  • PCB-M1631-04C

                  • S type load cell,
                  • Measuring range≥ 10 kΩ,
                  • Nominal 2 mV / V,
                  • Integrated cable, length 3 m,
                    ending on open ends
                    • PCB-M1631-06C

                    • S type load cell,
                    • Measuring range 20 kN,
                    • Nominal 2 mV / V,
                    • Integrated cable, length 3 m,
                      ending on open ends
                      • PCB-M1403-02B

                      • Load cell for static measurements,
                      • Measuring range 2,500 N,
                      • Nominal 1 mV / V,
                      • Anschlusskonnektor PC04E-10-6 p side illustration

                        shows load cell load base PCB M084A100 < br(separat erhältlich)
                        • PCB-(M)261A11

                        • Triaxial strength measuring element with charge output,
                        • Measuring range (Z axis) 4.45 kN,
                        • Measuring range (X - and Y-axes) 2.22 kN,
                        • Sensitivity (Z-axis) 3.4 pC/N,.
                        • Sensitivity (X - and Y-axes) 7.2 pC/N,.
                        • Upper frequency limit 10,000 Hz,.
                        • Three 10-32 connectors on the side