PCB-260M29
zoom_out_map

PCB-260M29

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 0.445 kN, 
  • Measuring range (X and Y axis) 0.444 kN, 
  • Sensitivity (Z-axis) 5.60 mV / N, 
  • Sensitivity (X and Y axis) 11.25 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.001 ... 90,000 Hz, 
  • 4-pin connection socket on the side
specifications
basic dataEnglish unitsSI units 
Sensitivity (Z-axis) (± 15%) 25 mV/lb 5,60 mV/N [2][3]
Sensitivity (X and Y axis) (± 15%) 50 mV/lb 11,25 mV/N [2][3]
Measuring range (Z-axis) 100 lb 0,445 kN
Measuring range (X and Y axis) 100 lb 0,444 kN
Maximum force (Z-axis) 1200 lb 5,33 kN
Maximum force (X and Y axis) 100 lb 0,445 kN
Maximum moment (Z-axis) 14 ft-lb 18,98 Nm
Maximum moment (X and Y axis) 13 ft-lb 17,63 Nm
Broadband resolution (Z-axis) 0,006 lbRMS 0,027 NRMS [1]
Broadband resolution (X and Y axis) 0,002 lbRMS 0,0089 NRMS [1]
Upper limit frequency 90.000 Hz
Lower limit frequency (Z-axis) (-5%) 0,01 Hz
Lower cutoff frequency (X and Y axis) (-5%) 0,001 Hz
linearity error ≤1 % FS [4]
Crosstalk (between X and Y axis) ±3 %
Crosstalk (between X / Y axis and Z axis) ±5 %
Operating conditions
temperature range -65 … 250 °F -54 … 121 °C
Technical characteristics
Maximum output signal (Z axis) ±2,5 VDC
Maximum output signal (X and Y axis) ±5 VDC
Discharge time constant (Z-axis) ≥50 s
Discharge time constant (X and Y axis) ≥500 s
Supply voltage (all axes) 20 … 30 VDC
Constant current supply (all axes) 2… 20 mA
output impedance ≤100 Ω
Bias voltage 8 … 14 VDC
Spectral noise (X and Y axis) (1 Hz) 0,0003 lb/√Hz 0,00134 N/√Hz
Spectral noise (X and Y axis) (10 Hz) 0,00015 lb/√Hz 0,000668 N/√Hz
Spectral noise (X and Y axis) (100 Hz) 0,00005 lb/√Hz 0,000223 N/√Hz
Spectral noise (X and Y axis) (1,000 Hz) 0,000015 lb/√Hz 0,0000668 N/√Hz
Spectral noise (Z-axis) (1 Hz) 0,0015 lb/√Hz 0,00668 N/√Hz
Spectral noise (Z-axis) (10 Hz) 0,00055 lb/√Hz 0,00245 N/√Hz
Spectral noise (Z-axis) (100 Hz) 0,0002 lb/√Hz 0,000891 N/√Hz
Spectral noise (Z-axis) (1.000 Hz) 0,000055 lb/√Hz 0,000245 N/√Hz
output polarity positive
Physical properties
preload 56 in-lb 6,3 Nm [5][6]
Stiffness (Z-axis) 10 lb/µin 1,75 kN/µm [1]
Stiffness (X and Y axis) 4 lb/µin 0,7 kN/µm [1]
Size - height 0,390 in 9,90 mm
Size - length 1,075 in 27,3 mm
Size - width 0,95 in 24,1 mm
Size - inside diameter 0,319 in 8,10 mm
Size - diameter of the measuring surface 0,680 in 17,27 mm
Mass 0,927 oz 26.27 grams
housing material stainless steel
seal Hermetically sealed
Electrical connection 4-Pin
port location Laterally

[6]

Hints
[1] typically,
[2] When using the recommended preload. The sensitivities may change by ± 5% depending on the preload used.
[3] The specified sensitivities apply only when using the supplied bolts.
[4] Zero-based balancing line, determined by the least squares method
[5] The preload should be at least ten times the operating range used on the X and Y axis.
[6] Details: siehe PCB Declaration of Conformance PS023

included supply
081A70 mounting bolts (1)
082B02 washer (1)
083A10 mounting sleeve (1)

Available options
(W) Waterproof cable connection
Kabelabgang Laterally
(M) Metric montage
included supply
M081A70 mounting bolts (1)
PCB-260M29

Specific References

Download

260M29_specs

Download (93.05k)

260M29_drawing

Download (84.95k)