PCB-M1403-03A
zoom_out_map

PCB-M1403-03A

  • Load cell for static measurements,
  • Measuring range 5,000 N,
  • Nominal 1 mV / V,
  • Anschlusskonnektor PT02E-10-6 p side illustration

    shows load cell load base PCB M084A100 < br(separat erhältlich)
  •  

    basic data
    measuring range 1,124 lb 5,000 N [1]
     
    value (±10%) 1.0 mV / V   [2]
     
    Linearity error ≤0.05% FS    
     
    hysteresis ≤0.05% FS    
     
    repeatability ≤0.02% FS    
     
    Resonance frequency 5,500 Hz    
     
    creep error 0.03%    
    conditions
    Ü berlastlimit 2,000 lb 8,900 N  
     
    maximum load (lateral force, F X, or F Y) 1,000 lb 4,450 N [4]
     
    Maximum load (bending moment M X or M Y) 500 in-lb 56 Nm [4]
     
    Maximum load (axial torque, M Z) 1,000 lb 113 Nm [4]
     
    temperature range (operation)

    -65 … 200 °F

    -54 … 93 ° C  
     
    temperature range (offset) 70 … 170 ° F 21 … 77 ° C  
     
    temperature impact on the Output (max) ±0, 002% of reading / ° F ±0, 0036% of reading / ° C [3]
     
    temperature effect on zero signal deviation (maximum) ±0. 001% FS / ° F /±0, 0018% FS / ° C [3]
    technical characteristics
    Bridge resistance 700 ?   [2]
     
    supply voltage (recommended) 10 V DC   [5]
     
    insulation resistance > 5,000 M ?    
     
    Zero signal deviation ≤1.0% FS    
    physical properties
    size - diameter 4.12 in 104.6 mm  
     
    size ße - height 1.37 in 34.8 mm  
     
    weight 2.88 lb 1.31 kg  
     
    Assembly threaded M16 x 2-4 h female    
     
    Housing material paintedSteel    
     
    sensor element strain    
     
    Assembly torque 23 Nm  
     
    Aspect ratio at full load 0.0005 in    
     
    Wiring PT02E-10-6 p    
     
    connection position side    
    notes
    [1] FS =. "Full Scale": full scale    
     
    [2] nominal    
     
    [3] over the compensated temperature range    
     
    [4] insulated load the load cell with the named power or with the designated moment < br(keine zusätzlichen Belastungen)    
     
    [5] Calibrated with 10 V DC supply voltage; Power supply with 5 … 20 V DC or V AC RMS possible    

    -65 … 200 °F

    PCB-M1403-03A

    Specific References

    Download

    M1403-03A_drawing.pdf

    Technical drawing

    Download (1.25M)

    M1403-03A_manual.pdf

    Operating instructions

    Download (2.22M)

    M1403-03A_specs.pdf

    Technical data sheet

    Download (21.67k)