List of products by brand PCB Piezotronics

PCB Piezotronics was founded in 1967 as a manufacturer of piezoelectric quartz sensors, accelerometers, and associated electronics for the measurement of dynamic pressure, force, and vibration. The unique expertise of the company was the incorporation of microelectronic signal conditioning circuitry within these sensors to make them easier to use and more environmentally compatible. These ICP® sensors gained wide popularity and became the foundation for the company's success.
Subsequent growth and steady investment in facilities, machinery, and equipment permitted a constant broadening of the product offering. Measurement capabilities expanded with the addition of piezoceramic, tourmaline, capacitive, piezoresistive, and strain gage sensing technologies. Ensuing products include industrial accelerometers, DC accelerometers, load cells, torque sensors, microphones, pressure transmitters, and calibration equipment.
Showing 973-984 of 1981 item(s)
Showing 973-984 of 1981 item(s)

PCB-260M21

  • Triaxial ICP® force sensor, 
  • Measuring range (Z-axis) 4.45 kN, 
  • Measuring range (X and Y axis) 0.044 kN, 
  • Sensitivity (Z axis) 22.5 mV / N, 
  • Sensitivity (X and Y axis) 122 mV / N, 
  • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
  • Frequency range (X and Y axis) 0.01 ... 90,000 Hz, 
  • 4-pin connection socket on the side

    PCB-260M29

    • Triaxial ICP® force sensor, 
    • Measuring range (Z-axis) 0.445 kN, 
    • Measuring range (X and Y axis) 0.444 kN, 
    • Sensitivity (Z-axis) 5.60 mV / N, 
    • Sensitivity (X and Y axis) 11.25 mV / N, 
    • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
    • Frequency range (X and Y axis) 0.001 ... 90,000 Hz, 
    • 4-pin connection socket on the side

      PCB-260M36

      • Triaxial ICP® force sensor, 
      • Measuring range (Z-axis) 45 N, 
      • Measuring range (X and Y axis) 45 N, 
      • Sensitivity (Z-axis) 110 mV / N, 
      • Sensitivity (X and Y axis) 110 mV / N, 
      • Frequency range (Z-axis) 0.01 ... 90.000 Hz, 
      • Frequency range (X and Y axis) 0.001 ... 90,000 Hz, 
      • 4-pin connection socket on the side

        PCB-740M04

        • ICP® strain sensor, 
        • Measuring range 900 με, 
        • Sensitivity 5 mV / με, 
        • Frequency range 0.5 ... 100,000 Hz, 
        • Integrated connection cable, length 3 meters,
          ending on 10-32 plug

          PCB-740M06

          • ICP® strain sensor, 
          • Measuring range 900 με, 
          • Sensitivity 2 pC / με, 
          • Frequency range 0.5 ... 100,000 Hz, 
          • Integrated connection cable, length 3 meters,
            ending on 10-32 plug

            PCB-JM240A03

            • ICP® strain sensor, 
            • Measuring range 300 με, 
            • Sensitivity 10 mV / με, 
            • Lower limit frequency 0.004 Hz, 
            • 10-32 connector on the side, 
            • Masseisolierung

              PCB-176A03

              • Pressure sensor with charge output for detecting combustion instability in turbines,
              • With ATEX / CSA approval,
              • Continuous use temperature up to 650 ° C,
              • With UHT-12™ sensor element,
                (no popcorn noise),
              • Measuring range 20 bar,
              • Sensitivity 232 pC/bar,
              • Frequency range up to 10,000 Hz,
              • Integrated hardline cable, length 3 m,
                ending on 7/16-27-connector

                PCB-176A04

                • Pressure sensor with charge output for detecting combustion instability in turbines,
                • Continuous use temperature up to 350 ° C,
                • With UHT-12™ sensor element,
                  (no popcorn noise),
                • Measuring range 20 bar,
                • Sensitivity 2.25 pC/kPa,
                • Frequency range up to 10,000 Hz,
                • 7/16-27-socket

                  PCB-176A05

                  • Pressure sensor with charge output for detecting combustion instability in turbines,
                  • With ATEX / CSA approval,
                  • Continuous use temperature up to 520 ° C,
                  • With UHT-12™ sensor element,
                    (no popcorn noise),
                  • Measuring range 5 bar,
                  • Sensitivity 750 pC/bar,
                  • Frequency range up to 8,000 Hz,
                  • Integrated hardline cable, length 3 m,
                    ending on 7/16-27-connector

                    PCB-176M03

                    • Pressure sensor with charge output for detecting combustion instability in turbines,
                    • With ATEX / CSA approval,
                    • Continuous use temperature up to 530 ° C,
                    • With UHT-12™ sensor element,
                      (no popcorn noise),
                    • Measurement range 1.4 bar,
                    • Sensitivity 247 pC/bar,
                    • Frequency range up to 10,000 Hz,
                    • Integrated hardline cable,
                      ending on 7/16-27-connector

                      PCB-176M07

                      • Pressure sensor with charge output for detecting combustion instability in turbines,
                      • With ATEX / CSA approval,
                      • Continuous use temperature up to 530 ° C,
                      • With UHT-12™ sensor element,
                        (no popcorn noise)
                      • Measurement range 1.4 bar,
                      • Sensitivity 247 pC/bar,
                      • Frequency range up to 1500 Hz,
                      • Integrated hardline cable,
                        ending on 7/16-27-connector

                        PCB-176M12

                        • Pressure sensor with charge output for detecting combustion instability in turbines,
                        • With ATEX / CSA approval,
                        • Continuous use temperature up to 530 ° C,
                        • With UHT-12™ sensor element,
                          (no popcorn noise),
                        • Measurement range 1.4 bar,
                        • Sensitivity 247 pC/bar,
                        • Frequency range up to 1500 Hz,
                        • Integrated hardline cable,
                          ending on 7/16-27-connector