      • Pressure sensor with charge output for detecting combustion instability in turbines,
      • With ATEX / CSA approval,
      • Continuous use temperature up to 650 ° C,
      • With UHT-12™ sensor element,
        (no popcorn noise),
      • Measuring range 20 bar,
      • Sensitivity 232 pC/bar,
      • Frequency range up to 10,000 Hz,
      • Integrated hardline cable, length 3 m,
        ending on 7/16-27-connector
      "< td colspan ="2 "> see curve below"
      Specifications
      Basic dataEnglish unitsSI units 
      Sensitivity (±20 %)16 pC/psi232 pC/bar 
      Measuring range290 psi20 bar 
      Maximum pressure (total)2,000 psi137.9 bar 
      Resonance frequency≥50.000 Hz 
      Transverse resonance≥10.000 Hz 
      Upper frequency limit10,000 Hz[2] [3]
      Linearity error≤1% FS[1]
      Conditions of use
      Acceleration sensitivity0.003 psi/g0,00021 bar / g[4]
      Acceleration sensitivity0,00069 bar / g[5]
      Temperature range (operation)-94... 1200 °F-70... 650 ° C 
      Temperature range (connector)-76... 500 ° F-60... 260 ° C 
      Influence of temperature 
      Approved for use in potentially explosive atmospheresSee operating instructions 
      Maximum exposure (integrated gamma flux)100,000,000 wheel 
      Maximum exposure (integrated neutron flux)10.000.000.000 N / cm² 
      Technical properties
      Output polarityDifferential 
      capacity (with cable from pin to pin)170 pF[6]
      Internal resistance (at room temperature)≥1012Ω 
      Isolation resistance (at room temperature)≥1012Ω 
      Internal resistance (at 650 ° C)?50 kΩ 
      Isolation resistance (at 650 ° C)≥100 kΩ 
      Physical properties
      Sensor elementUHT-12™ 
      Geometry of the sensor elementCompression principle 
      Housing materialNickel alloy 
      SealingHermetically sealed welded 
      Electrical connection2-pin connector with 7/16-27 thread 
      Cable typeHardline cable with braided shield 
      Cable length10 ft3 m 
      Weight (with cables)17.6 oz500 grams 
      Notes
      [1]Zero-balance just, determined using the method of least squares  
      [2]The lower cut-off frequency depends on the used signal conditioning electronics.  
      [3]Upper frequency limit is calculated on the basis of the resonance frequency  
      [4]Nominal  
      [5]Maximum  
      [6]Typically  
      [7]Details: see PCBs Declaration of conformance PS058