Piezoelectric pressure sensors-

Piezoelectric Pressure Sensor

.

Showing 49-60 of 107 item(s)
Showing 49-60 of 107 item(s)

Active filters

PCB-138A50

  • Tourmaline-ICP® pressure sensor,
  • For underwater use,
  • Measuring range 344.750 kPa,
  • Sensitivity 0.015 mV / kPa,
  • Length 193 mm,
  • 10-32 female connector < br(optional mit wasserdichter Kabelverbindung)
    • PCB-(M)121A23

    • ICP® pressure sensor with stainless steel membrane,
    • For industrial applications,
    • Measuring range 34.473 kPa,
    • Sensitivity 0.145 mV / kPa,
    • Lower limiting frequency 0.005 Hz,
    • 2-pin connector
      • PCB-137B22A

      • ICP® pressure sensor,
      • For blast pressure measurements
      • Measuring range 3.450 kPa,
      • Sensitivity 1.45 mV / kPa,
      • 10-32 female connector
        • PCB-138A51

        • Tourmaline-ICP® pressure sensor,
        • For underwater use,
        • Measuring range 344.750 kPa,
        • Sensitivity 0.015 mV / kPa,
        • Length 120 mm,
        • 10-32 female connector < br(optional mit wasserdichter Kabelverbindung)
          • PCB-102M206

          • ICP® pressure sensor with stainless steel membrane,
          • With ATEX / CSA approval,
          • Masseisoliert,
          • Beschleunigungskompensiert,
          • Measuring range 344,8 kPa,
          • Sensitivity 14.5 mV / kPa,
          • Lower limiting frequency 0.5 Hz,
          • 10-32 female connector
            • PCB-(M)109C11

            • ICP® pressure sensor with ceramic-coated Cone,
            • For ballistic applications
            • Beschleunigungskompensiert,
            • Measuring range 552,000 kPa,
            • Sensitivity 0.01 mV / kPa,
            • Schockgeschützt up to 50,000 g,
            • 10-32 female connector
              • PCB-113B26

                • ICP® high frequency pressure sensor with INVAR-membrane,
                • Beschleunigungskompensiert,
                • Measuring range 3.450 kPa,
                • Sensitivity 1.45 mV / kPa,
                • Lower limiting frequency 0.01 Hz,
                • 10-32 female connector

                  PCB-(M)103B01

                • ICP® pressure sensor with stainless steel membrane,
                • For turbulence measurements,
                • Measuring range 20.7 kPa (180.3 dB),
                • Sensitivity 217.5 mV / kPa,
                • Lower limiting frequency 0.5 Hz,
                • Integrated cable, length 38 cm,
                  ending on stripped and tinned ends
                  • PCB-(M)109C12

                  • ICP® pressure sensor with ceramic-coated Cone,
                  • For ballistic applications
                  • Beschleunigungskompensiert,
                  • Measuring range 690.000 kPa,
                  • Sensitivity 0.01 mV / kPa,
                  • Schockgeschützt up to 50,000 g,
                  • 10-32 female connector
                    • PCB-113B27

                      • ICP® high frequency pressure sensor with INVAR-membrane,
                      • Beschleunigungskompensiert,
                      • Measuring range 689,4 kPa,
                      • Sensitivity 7.25 mV / kPa,
                      • Lower limiting frequency 0.5 Hz,
                      • 10-32 female connector

                        PCB-(M)103B02

                      • ICP® pressure sensor with stainless steel membrane,
                      • For turbulence measurements,
                      • Measuring range 20.7 kPa (180.3 dB),
                      • Sensitivity 217.5 mV / kPa,
                      • Lower limiting frequency 0.5 Hz,
                      • 10-32 female connector
                        • PCB-111A21

                          • ICP® pressure sensor with INVAR-membrane,
                          • Beschleunigungskompensiert,
                          • Measuring range 689.5 kPa,
                          • Sensitivity 5.8 mV / kPa,
                          • Lower limiting frequency 0.5 Hz,
                          • 10-32 female connector