PCB-137B21A
zoom_out_map

PCB-137B21A

  • ICP® pressure sensor,
  • For blast pressure measurements
  • Measuring range 6,900 kPa,
  • Sensitivity 145 mV / PA,
  • 10-32 female connector
  • basic data
    measuring range (output range ±1 V) 1 kpsi 6.895 kPa
    sensitivity (±15%) 1 mV / psi 0.145 mV / kPa
    Maximum pressure 5 kpsi 34.474 kPa
    resolution 8.5 mpsi 0.059 kPa [1]
    resonance frequency ≥ 400,000 Hz
    rise time (unwittingly pressure) ≤ 6.5 µs
    linearity ≤ 1.0% FS [2]
    conditions
    temperature range (operation) -100 … 275 ° F -73 … 135 ° C
    Temperature coefficient of sensitivity ≤0,05 %/°F ≤ 0,090 %/°C
    technical properties
    discharge charge time constant (at room temperature) ≥ 0.2 s
    Supply 20 … 30 V DC
    constant power supply 2 … 20 mA
    Output impedance≤ 100 Ω
    Bias voltage 8 … 14 V DC
    physical properties
    geometry of the Sensor element compression principle
    sensor element quartz
    housing material aluminum
    Membrane INVAR
    waterproofing epoxy resin
    wiring 10-32-coaxial socket
    Dimensions 12.5 oz 354 grams [1]
    notes
    [1] typically
    [2] zero-based balancing line, determined using the method of least squares
    [3] details: see PCBs Declaration of conformance PS023
    Accessories
    085A43 Konnektorschutz -1
    PC-6 calibration series 134, 137, and 138 -1
    PCB-137B21A

    Specific References

    Download

    137B21A_drawing.PDF

    Technical drawing

    Download (330.13k)

    137B21A_manual.PDF

    Operating instructions

    Download (963.07k)

    137B21A_specs.PDF

    Technical data sheet

    Download (27.74k)