PCB-(M)109C11
| basic data | |||
| measuring range | 80,000 psi | kPa 552.000 | |
| usable range | 100,000 psi | 690,000 kPa | |
| Sensitivity (±15%) | 0.07 mV / psi | 0.010 mV / kPa | |
| maximum pressure | 125,000 psi | kPa 862.000 | |
| release Sung | ≤2.0 psi | ≤13.8 kPa | |
| resonance frequency | ≥400,000 Hz | ||
| rise time | ≤ 2 µs | ||
| Linearity | ≤2.0% FS | [2] | |
| conditions | |||
| acceleration sensitivity | ≤0.02 psi/g | ≤0.015 kPa/(m/s²) | |
| Temperature range (operation) | -100 … 275 ° F | -73 … 135 ° C | |
| Temperature coefficient of sensitivity | ≤0.07 %/°F | ≤ 0,126 %/°C | |
| maximum shock (for fraction of a second) | 3,000 ° F | 1,650 ° C | |
| maximum acceleration | 2,000 g PK | 19.620 m/s² pk | |
| Maximum shock resistance | 50,000 g pk | 490.330 m/s² pk | |
| Technical characteristics | |||
| Output polarity (positive pressure) | positive | ||
| Discharging charging time constant (at room temperature) | ≥ 2,000 s | ||
| supply | 20 … 30 V DC | ||
| Constant power supply | 2 … 20 mA | ||
| output impedance | ≤100 Ω | ||
| Bias voltage | 8 … 14 V DC | ||
| Physical properties | |||
| geometry of the sensor element | compression principle | ||
| sensor element | quartz | ||
| Housing material | C-300 | ||
| membrane | C-300 | [1] | |
| Sealing | epoxy resin | ||
| electrical connection | 10-32-coaxial socket | ||
| weight | 0.6 oz | 17 grams | |
| Notes | |||
| [1] | Keramikbeschichtet | ||
| [2] | zero-based balancing line, determined using the method of least squares | ||
| [3] | details: see PCBs Declaration of conformance PS023 | ||
| Equipment | |||
| 065A06 | sealing ring, 0,318 "outside x 0.250" x 0.010 "high, 316 L (stainless steel) | 3 | |
| (M) metric mounting | |||