Active filters

TMS-2100E11

  • Modal Shaker
  • Force 440 N,.
  • Frequency range 0... 5,400 Hz,
  • Stroke 25.4 mm

    Strobe model HELIO STROB micro2

    • extremely bright Super brilliant CREE led - technology < b>(3800 Lux)
    • handy and easy (175 Gr.) as a mobile phone
    • Flash time adjustable
    • maintenance-free industrial quality
    • Flash frequencies up to 2000 Hz
    • Speedometer - mode
    • with trigger input.

      Expert software model DDS

      • Windows 7 and later compatible
      • Supports Microsoft SQL Server,
      • "Online" or "Offline" operation possible,
      • Intelligent cursor functions (harmonic, sideband, trend...)
      • Input of gears kinematics,
      • Implementation of warehouse database

        TMS-2075E

        • Dual purpose Shaker,
        • For the modal analysis as well as for part / component testing,
        • Maximum force 334 N,.
        • Frequency range 0... 6,500 Hz,
        • Stroke 25 mm

          Strobe model HELIO STROB tripLED

          • Strobe Helio Strob tripLED
          • Flash frequency up to 840 Hz (50'400 RPM)
          • intelligent one-button control
          • convenient touch panel control
          • high, constant brightness to 5'500 lux (50 cm)
          • Battery - and mains operation
          • "Slow Motion" function < / li>
          • "Software prescaler" adjustable < / li>
          • internal and external triggering
          • with TTL trigger output

            TMS-2110E

            • Dual purpose Shaker
            • For the modal analysis as well as for part / component test
            • Maximum force 489 N
            • Frequency range 0... 6,500 Hz
            • Stroke 25 mm

              DNA software

              • Download of data from the instruments or the USB stick (Flash memory).
              • Representation of as many "live" data indicators,
              • Graphics as 1/1, 1/3, 1/12, 1/24 octave or FFT and zoom-FFT, SLM level histories and level statistics,
              • Create "Templates" for quick report generation,
              • Integration of text, graphics, images and OLE objects (Excel, Word, sound,...) in the report.
              • RT-60 with backward Schroeder Integration
              • ISO 10140, ISO140, ISO 16283, ISO 717
              • ASTM E336, ASTM E966, ASTM E1007

                TMS 396Cxx

                • Graphite / air,
                • Minimum lateral excitation
                • Calibration standard COM. ISO16063-21
                • Deflection (continuous) 10 mm peak peak,.
                • Frequency range 2 Hz... 20 kHz (no load),
                • "Lorentz force lifting",
                • integrated reference sensor

                  Strobe A4950

                  • High performance LEDs with lens and reflector system,
                  • Flashing 0.5 Hz - 500 Hz frequency range (30 RPM up to 30'000 RPM).
                  • Flash frequency divider and multiplier,
                  • Control the Flash duration,
                  • Adjustable phase ± 180 °
                  • Internal or external triggering,
                  • Power supply for external laser tacho probe,
                  • Trigger output for external device
                  • Powered by 2 AA batteries,

                    Power amplifier SmartAmp

                    • Power amplifier with 400W,
                    • great Bandbreist (0 Hz... 40 kHz),
                    • up to 18 A output current,.
                    • up to 38 V output voltage,
                    • 92% efficiency,
                    • Overcurrent protection,
                    • Ütemperaturschutz,
                    • Interlock input