Sound Measurement

.

Showing 49-60 of 69 item(s)
Showing 49-60 of 69 item(s)

Active filters

PCB-377B20

  • Prepolarized 1/2 "precision microphone for diffuse field applications,
  • sensitivity 50 mV / PA,
  • dynamic range > 144 dB,
  • frequency range 3.15..." 12,500 Hz,
    • no longer available (replacement: PCB-377 C 20)

    PCB-378C10

  • 1/4 "-ICP® precision microphone for pressure applications,
  • Combination of microphone capsule PCB-377 C-10 and preamp PCB-426 B 03,
  • Sensitivity 1.0 mV / PA,
  • Dynamic range > 174 dB,
  • Frequency range 5 … 70,000 Hz,
  • 10-32 socket
  • As system calibrated
    • PCB-130A23

    • ICP® array free field microphone,
    • With TEDS 1.0,
    • Diameter 7 mm,
    • Sensitivity 14 mV / PA,
    • Dynamic range > 143 dB,
    • Frequency range 20 … 20,000 Hz,
    • SMB connector
      • PCB-130A24

        • Wasserdichtes ICP®-Array-free-fieldmikrofon,
        • Ideal für Akustikmessungen an Fahrzeugbremsen,
        • Mit TEDS 1.0,
        • Durchmesser 13,2 mm,
        • Empfindlichkeit 10 mV/Pa,
        • Dynamikbereich >143 dB,
        • Frequenzbereich 20 … 16.000 Hz,
        • BNC-Anschlussbuchse

          PCB-130B40

          • ICP® surface microphone,
          • with TEDS 1.0,
          • sensitivity 8.5 mV / PA,
          • dynamic range > 142 dB,
          • frequency range 20... 20,000 Hz,
          • integrated cable, length 1.5 m,
            ending on 10-32 plug

            PCB-106B

          • ICP® pressure sensor with stainless steel membrane,
          • For acoustic measurements,
          • Beschleunigungskompensiert,
          • Measuring range 57.2 kPa,
          • Lower limiting frequency 2.5 Hz,
          • 10-32 female connector
            • PCB-106B50

            • ICP® pressure sensor with stainless steel membrane,
            • For acoustic measurements,
            • Beschleunigungskompensiert,
            • Measuring range 34,45 kPa,
            • Sensitivity 72.5 mV / kPa,
            • Lower limiting frequency 0.5 Hz,
            • 10-32 female connector
              • PCB-106B51

              • ICP® pressure sensor with stainless steel membrane,
              • For acoustic measurements,
              • Beschleunigungskompensiert,
              • Measuring range 35 kPa,
              • Sensitivity 145 mV / kPa,
              • Lower limiting frequency 0.5 Hz,
              • 10-32 female connector
                • PCB-106B52

                • ICP® pressure sensor with stainless steel membrane,
                • For acoustic measurements,
                • beschleunigungskompensiert,
                • Measuring range 6.89 kPa,
                • Sensitivity 725 mV / kPa,
                • Lower limiting frequency 0.5 Hz,
                • 10-32 female connector
                  • PCB-106M131

                  • ICP® pressure sensor with stainless steel membrane,
                  • For acoustic measurements,
                  • Beschleunigungskompensiert,
                  • Measuring range 57.2 kPa,
                  • Sensitivity 36.2 mV / kPa,
                  • Lower limiting frequency 0.5 Hz,
                  • 10-32 female connector
                    • Precision sound level meter LD-831

                      • Integrating precision sound level meter,
                      • LCD display with high contrast,
                      • Time reviews: Slow, fast pulse, integration, and peak at the same time,
                      • Frequency weighting: A, C, Z at the same time (AnyData),.
                      • Octave and octave band frequency analysis,
                      • Voice commentary & sound recording
                      • standards IEC 60651, IEC 60804, IEC 61260, IEC 61672,
                      • With METAS, PTB approval class 1

                        LD-CAL200

                        • Battery powered Mikrofonkalibrator
                        • Sound pressure level of 94 or 114 dB,
                        • Frequency 1,000 Hz,.
                        • complies with IEC 60942-2017 standard (class 1),
                        • To the off Calibration METAS, PTB approved