Sound Measurement

.

Showing 37-48 of 68 item(s)
Showing 37-48 of 68 item(s)

Active filters

PCB-378A21

  • 1/2 "-ICP® precision microphone for diffuse field applications,
  • Combination of microphone capsule PCB 377A21 and preamp PCB-426E01,
  • Sensitivity 12.6 mV / PA,
  • Dynamic range > 147 dB,
  • Frequency range 4 … 25,000 Hz,
  • BNC connector,
  • As system calibrated

    PCB-377A13

  • Prepolarized 1/2 "precision microphone capsule for pressure applications,
  • Sensitivity 12.6 mV / PA,
  • Dynamic range > 155 dB,
  • Frequency range 4 … 20,000 Hz
    • PCB-378B02

      • 1/2 "-ICP® precision microphone for free-field applications,
      • Combination of microphone capsule PCB-377 B 02 / preamp PCB-426E01,
      • Sensitivity 50 mV / PA,
      • Dynamic range > 135 dB,
      • Frequency range 3.75 … 20,000 Hz,
      • BNC connector,
      • As system calibrated

        PCB-377A14

      • Prepolarized 1/4 "precision microphone capsule for pressure applications,
      • Sensitivity 1.0 mV / PA,
      • Dynamic range > 174 dB,
      • Frequency range 4 … 70,000 Hz
        • PCB-378B11

        • 1/2 "-ICP® precision microphone for pressure applications,
        • Combination of microphone capsule PCB-377 B 11 / preamp PCB-426E01,
        • Sensitivity 50 mV / PA,
        • Dynamic range > 135 dB,
        • Frequency range 3.75 … 10,000 Hz,
        • BNC connector,
        • As system calibrated
          • PCB-377B02

            • Prepolarized 1/2 "precision microphone for free-field applications,

            "

            • Sensitivity 50 mV / PA,
            • Dynamic range > 146 dB,
            • Frequency range 3.15 … 20,000 Hz

              PCB-378B20

              • 1/2 "-ICP® precision microphone for diffuse field applications,
              • Combination of microphone capsule PCB-377 B 20 and preamp PCB-426E01,
              • Sensitivity 50 mV / PA,
              • Dynamic range > 135 dB,
              • Frequency range 3.75 … 12,500 Hz,
              • BNC connector,
              • As system calibrated,
              • No longer available (replacement: PCB-378C20)

                PCB-377B11

              • Prepolarized 1/2 "precision microphone capsule for pressure applications,
              • Sensitivity 50 mV / PA,
              • Dynamic range > 143 dB,
              • Frequency range 3.15 … 10,000 Hz
                • PCB-378C01

                • 1/4 "-ICP® precision microphone for free-field applications,
                • Combination of microphone capsule PCB-377 C-01 and preamp PCB-426 B 03,
                • Sensitivity 2.0 mV / PA,
                • Dynamic range > 162 dB,
                • Frequency range 4 … 100,000 Hz,
                • 10-32 socket
                • As system calibrated
                  • PCB-377B20

                    • Prepolarized 1/2 "precision microphone for diffuse field applications,
                    • sensitivity 50 mV / PA,
                    • dynamic range > 144 dB,
                    • frequency range 3.15..." 12,500 Hz,
                      • no longer available (replacement: PCB-377 C 20)

                      PCB-378C10

                    • 1/4 "-ICP® precision microphone for pressure applications,
                    • Combination of microphone capsule PCB-377 C-10 and preamp PCB-426 B 03,
                    • Sensitivity 1.0 mV / PA,
                    • Dynamic range > 174 dB,
                    • Frequency range 5 … 70,000 Hz,
                    • 10-32 socket
                    • As system calibrated
                      • PCB-377B26

                      • ICP® probe microphone,
                      • Sensitivity 2.15 mV / PA,
                      • Dynamic range > 164 dB,
                      • Frequency range 2 … 20,000 Hz,
                      • BNC connector,
                      • Including tools, probes and transport case