Sound Measurement

.

Showing 37-48 of 68 item(s)
Showing 37-48 of 68 item(s)

Active filters

PCB-377B11

  • Prepolarized 1/2 "precision microphone capsule for pressure applications,
  • Sensitivity 50 mV / PA,
  • Dynamic range > 143 dB,
  • Frequency range 3.15 … 10,000 Hz
    • PCB-378C01

    • 1/4 "-ICP® precision microphone for free-field applications,
    • Combination of microphone capsule PCB-377 C-01 and preamp PCB-426 B 03,
    • Sensitivity 2.0 mV / PA,
    • Dynamic range > 162 dB,
    • Frequency range 4 … 100,000 Hz,
    • 10-32 socket
    • As system calibrated
      • PCB-377B20

        • Prepolarized 1/2 "precision microphone for diffuse field applications,
        • sensitivity 50 mV / PA,
        • dynamic range > 144 dB,
        • frequency range 3.15..." 12,500 Hz,
          • no longer available (replacement: PCB-377 C 20)

          PCB-378C10

        • 1/4 "-ICP® precision microphone for pressure applications,
        • Combination of microphone capsule PCB-377 C-10 and preamp PCB-426 B 03,
        • Sensitivity 1.0 mV / PA,
        • Dynamic range > 174 dB,
        • Frequency range 5 … 70,000 Hz,
        • 10-32 socket
        • As system calibrated
          • PCB-377B26

          • ICP® probe microphone,
          • Sensitivity 2.15 mV / PA,
          • Dynamic range > 164 dB,
          • Frequency range 2 … 20,000 Hz,
          • BNC connector,
          • Including tools, probes and transport case
            • PCB-378C20

            • 1/2 "-ICP® precision microphone for diffuse field applications,
            • Combination of microphone capsule PCB-377 C 20 and preamp PCB-426E01,
            • Sensitivity 50 mV / PA,
            • Dynamic range > 135 dB,
            • Frequency range 3.75 … 16,000 Hz,
            • BNC connector,
            • As system calibrated
              • PCB-377C01

                • Prepolarized 1/4"-Präzisionsmikrofonkapsel
                  für free-fieldanwendungen,
                • Empfindlichkeit 2,0 mV/Pa,
                • Dynamikbereich >164 dB,
                • Frequenzbereich 3 …≥100.000 Hz

                  PCB-426A05

                • ICP® preamplifiers for 1/4 "headsets with lateral pressure equalization,
                • Gain - 0.19 dB,
                • Frequency range 0.7 … 126,000 Hz,
                • Incl. TEDS memory chip
                  • PCB-377C10

                  • Prepolarized 1/4 "precision microphone capsule for pressure applications,
                  • Sensitivity 1.0 mV / PA,
                  • Dynamic range > 174 dB,
                  • Frequency range 4 … 70,000 Hz
                    • PCB-426A07

                    • Short ICP® preamplifiers for 1/4 "-microphones,
                    • Gain - 0.2 dB,
                    • Frequency range 0.7 … 126,000 Hz,
                    • Incl. TEDS memory chip
                      • PCB-377C20

                        • Prepolarized 1/2"-Präzisionsmikrofonkapsel
                          für Diffusfeldanwendungen,
                        • Empfindlichkeit 50 mV/Pa,
                        • Dynamikbereich >144 dB,
                        • Frequenzbereich 3,15 … 16.000 Hz

                          PCB-426A10

                          • ICP® preamplifiers for 1/2 "-microphones, < / l"i >
                          • 20 Hz high-pass filter,.
                          • Gain - 0.1 dB,
                          • Frequency range 10... 125,000 Hz
                          • Including the TEDS memory chip