PCB-(M)350B03
    zoom_out_map

      PCB-(M)350B03

    • ICP® shock acceleration sensor,
    • With electric and mechanical filter,
    • Measuring range 10,000 g,
    • Sensitivity 0.5 mV / g,
    • Frequency range 0.4 … 10,000 Hz,
    • 10-32 female connector above,
    • No longer available (replacement: PCB-(M)350C03)
    • basic data
      sensitivity (±30%)0.5 mV / g0.05 mV/(m/s²)
      range±10. 000 g PK±98. 000 m/s² pk
      Frequency range (± 1 dB)0.4 … 10,000 Hz
      frequency range (-3 dB)0.2 … 25,000 Hz[1]
      Corner frequency of the electrical filter (-3 dB)13,000 Hz[2] [4]
      resonance frequency of the mechanical filter23,000 Hz[2] [3]
      Resonance frequency≥ 100,000 Hz
      wide band resolution0.04 g RMS0.39 m/s² RMS[2]
      Linearity≤ 2.0%
      transverse acceleration sensitivity≤ 7%
      conditions of use
      Overload limit (shock)±50. 000 g pk±490. 000 m/s² pk
      temperature range (operation)0 … 150 ° F-18 … 66 ° C
      Temperature range (storage)-40 …200 °F-40 … 93 ° C
      strain sensitivity (footprint)0,002 g/µε0.02 (m/s ²) / µ ε[2]
      specifications
      power supply20 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤200Ω
      Bias voltage8 … 14 V DC
      Discharging charging time constant1.0 … 2.0 s
      settling time < br(auf Bias-Spannung ±10 %)>10s
      Physical properties
      Sensor elementceramic
      Geometry of the sensor elementshear principle
      Housing materialtitanium
      sealinghermetically sealed
      size - hex 0.375 in9.5 mm
      size - height1.02 in25.9 mm
      mass0.16 oz4.5 grams[2]
      Electrical connection10-32-coaxial socket
      connection positionabove
      mounting thread1/4 "-28-au" ßengewinde
      notes
      [1]the specified upper limit frequency is a guideline. The frequency response is limited by the combination of electric and mechanical low pass filter.
      [2]typically
      [3]the amplitude is increased in the resonance frequency by 9 dB.
      [4]second-order low-pass filter
      [5]details: see PCBs Declaration of conformance PS023
      Supplied accessoriesr
      ACS-14Hopkinson bar calibration for shock resistance-1
      ACS-22frequency response, traceable to NIST (100 Hz to ±1dB point)-1
      (M) metric mounting
      mounting threadM6 x 0.75 male
      (W) waterproof cable
      wiring Integrated cable
      PCB-(M)350B03

      Specific References

      Download

      350B03_drawing.PDF

      Technical drawing

      Download (39.03k)

      350B03_manual.PDF

      Operating instructions

      Download (1.63M)

      350B03_specs.PDF

      Technical data sheet

      Download (31.55k)