PCB-HT(M)602D11
zoom_out_map

PCB-HT(M)602D11

  • Industrial ICP® vibration sensor,
  • Continuous use temperature up to 163 ° C,
  • With through hole,
  • Measurement range 50 g,
  • Sensitivity 100 mV/g,
  • Frequency range 0.8 … 8,000 Hz,
  • One-point calibration at 100 Hz,
  • Integrated cable, length 3 m,
    ending on cut end
  • basic data
    sensitivity (±10%) 100 mV/g 10.2 mV/(m/s²) [1]
    measuring range ±50 g ±490 m / s²
    Frequency range (± 3 dB) 48 … 480,000 cpm 0.8 … 8,000 Hz [4] [5]
    resonance frequency 1,500 kcpm 25,000 Hz [2]
    Wide band resolution 150 µg 1.472 µm / s ² [2]
    linearity ≤1% [3]
    Transverse acceleration sensitivity ≤ 5%
    conditions of use
    Overload limit (shock) 5,000 g pk 49,050 m/s² pk
    temperature range -65 … 325 ° F -54 … 162 ° C
    Type of protection IP67
    Technical characteristics
    settling time (on bias voltage ± 1%) ≤ 2.0 s
    discharging charging time constant ≥ 0.2 s
    Power 18 … 28 V DC
    constant power supply 2 … 20 mA
    Output impedance < 150 Ω
    Bias voltage 8 … 12 V DC
    Spectral noise (10 Hz) 9.0 µg / √ Hz 88,3 (µm / s ²) / √ Hz [2]
    spectral noise (100 Hz) 4.0 µg / √ Hz 39.2 (µm / s ²) / √ Hz [2]
    spectral noise (1,000 Hz) 2.0 µg / √ Hz 19.6 (µm / s ²) / √ Hz [2]
    Electrical insulation ≥ 100 MΩ
    physical properties
    size - length 2.1 in 53.3 mm
    size ße - width 1.0 in 25.4 mm
    size - height 1.0 in 25.4 mm
    dimensions (without cable) 5.4 oz 153 grams
    Assembly torque 2 … 5 ft-lb 2.7 … 6.8 Nm
    sensor element ceramic
    geometry of the sensor element Shear principle
    Housing material stainless steel
    electrical connection integrated cable
    Cable outlet On the side
    Cable termination cut end
    electrical connection (white wire) signal / supply
    Electrical connection (black wire) ground
    cable length 10 ft 3.0 m
    cable type type 055. screened two-core cable with Teflon coating and reinforcing
    notes
    [1] conversion factor 1 g = 9.81 m/s²
    [2] Typically
    [3] zero-based balancing line, determined using the method of least squares
    [4]The upper cut-off frequency tolerance: ±10%
    [5] 1 Hz 60 = cpm ("Cycles Per Minute": rpm).
    [6] details: see PCBs Declaration of conformance PS023
    equipment
    081A73 mounting screw 1/4 "-28 x 1.34 " -1
    (M) metric mounting
    equipment
    M081A73 metric mounting bolt with M6 threads -1
    PCB-HT(M)602D11

    Specific References

    Download

    HT602D11_drawing.PDF

    Technical drawing

    Download (386k)

    HT602D11_manual.PDF

    Operating instructions

    Download (1.14M)

    HT602D11_specs.PDF

    Technical data sheet

    Download (645.56k)