PCB-393B12
basic data | |||
sensitivity (±10%) | /10,000 mV / g | 1,019.4 mV/(m/s²) | |
range | 0.5 g pk | 4.9 m/s 2 pk | |
frequency range (±5%) | 0.15 … 1,000 Hz | ||
Frequency range (± 10%) | 0.10 … 2,000 Hz | ||
Frequency range (± 3 dB) | 0.05 … 4,000 Hz | ||
resonance frequency | ≥ 10,000 Hz | ||
phase response ( ±5 °) | 1 … 1.000 Hz | ||
wide band resolution | 0,000008 g RMS | 0.00008 m/s² RMS | [1] |
Linearity | ≤ 1% | [2] | |
transverse acceleration sensitivity | ≤ 7.0% | ||
conditions of use | |||
Overload limit (shock) | ±5. 000 g pk | ±49. 050 m/s² pk | |
temperature range | 50 … 180 ° F | 45 … 82 ° C | |
Strain sensitivity (base area) | ≤ 0.0005 g/µε | ≤ 0.005 (m/s²)/µε | [1] |
specifications | |||
power supply | 18 … 30 V DC | ||
constant power supply | 2 … 20 mA | ||
output impedance | < 1,500 Ω | ||
Bias voltage | 8 … 12 V DC | ||
discharging charging time constant | ≥ 3<5 s | ||
settling | < 60 s | ||
spectral noise (1 Hz) | 1.30 µg / √ Hz | 12,7 (µm / s ²) / √ Hz | [1] |
spectral noise (10 Hz) | 0.32 µg / √ Hz | 3.1 (µm / s ²) / √ Hz | [1] |
spectral noise (100 Hz) | 0.13 µg /. √ Hz | 1.3 (µm / s ²)/ √ Hz | [1] |
spectral noise (1,000 Hz) | 0.10 µg / √ Hz | 1.0 (µm / s ²) / √ Hz | [1] |
electrical insulation (housing) | ≥100 MΩ | ||
physical properties | |||
sensor element | ceramic | ||
geometry of the sensor element | shear principle | ||
Housing material | stainless steel | ||
sealing | hermetically sealed | ||
Gr öße - hex | 1 3/16 in | 30.2 mm | |
size - height | 2 3/16 in | 55.6 mm | |
mass | 7.4 oz | 210 grams | [1] |
electrical connection | 2-pin connector (MIL-C-5015) | ||
connection position | above | ||
Mounting thread | 1/4 "-28 threaded | ||
Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | |
notes | |||
[1] | " Typically | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
[3] | details: see PCBs Declaration of conformance PS023 | ||
Accessories | |||
081 B 20 | mounting bolts, with shoulder (1/4 "-28 1/4" 28) | -1 | |
085A31 | protection | -1 | |
ACS-1 | frequency response, traceable to NIST (10 Hz up to the upper 5% point) | -1 | |
ACS-4 | Low frequency calibration (phase and amplitude) of 0.5 … 10 Hz | -1 | |
M081B20 | mounting bolts 1/4 "28 M6 x 0.75 | -1 |