    basic data
    sensitivity (at 10 V DC supply voltage) (±50%)0.003 mV / g0.0003 mV/(m/s²)[2]
     
    sensitivity0.0003 mV / V / g0,00003 mV/V/(m/s²)[7]
     
    Range±60. 000 g±588. 400 m/s² pk 
     
    frequency range (1 dB)0 … 20,000 Hz  
     
    Resonance frequency> 120,000 Hz  
     
    damping rate2% crit chance [1]
     
    Linearity error≤1%  
     
    transverse acceleration sensitivity≤3%  
    conditions
    Ü berlastlimit (shock)±100. 000 g pk±980. 665 m/s² pk[6]
     
    Ü berlastlimit (mechanical stop)≥80,000 g? 782.534 m/s² pk 
     
    temperature range (storage)-65 … 250 ° F-54 … 121 ° C 
     
    temperature range (operation)-65 … 250 ° F-54 … 121 ° C 
     
    Temperature coefficient of sensitivity-0.11 %/°F-0.20 %/°C[1]
     
    Max thermal offset shift±10 mV [3]
     
    Strain sensitivity (base area)0,3 g/µε2.94 (m/s²)/µε[1]
    specifications
    power supply voltage (max)15.0 V DC  
     
    power< 3 mA  
     
    input resistance (±2 k Ω)6,000Ω [2]
     
    output impedance (kΩ ±2)6,000Ω [2]
     
    Spannungsoffset40 … 40 mV DC [2]
     
    settling time0.01 s [4]
     
    electrical insulation (housing)≥100 MΩ [5]
    PhysicalProperties
    sensor elementPiezoresistive MEMS element  
     
    geometry of the sensor elementActive bridge circuit  
     
    Housing materialtitanium  
     
    waterproofingepoxy resin  
     
    size - hex3/8 in9.5 mm 
     
    size - height0.50 in12.7 mm 
     
    dimensions (without cable)0.088 oz2.5 grams[1]
     
    Electrical connectionintegrated cable  
     
    Connection positionside  
     
    cord typetype 034, 4-wire shielded cable  
     
    cable terminationTinned ends  
     
    cable length10 ft3 m 
     
    mountingfixed external thread  
     
    Mounting thread1/4 "-28 thread  
    notes
    [1]typically  
     
    [2]Pro sensor tested and documented on calibration certificate supplied with  
     
    [3]-54 … 121 ° C, reference 24 ° C  
     
    [4]settling time is zero on ±2 at the time, the maximum needed the sensor signal, after the supply voltage is applied to approximate % of the output span. The mounting surface must be located in the thermal balance.  
     
    [5]Pro sensor tested to ensure compliance with the specification  
     
    [6]a half-sine pulse ≤ 20 µs  
     
    [7]Temperature coefficient of sensitivity is proportional to the applied supply voltage and can use a different voltage than at the calibration (10 V DC) ) are calculated from the calibration data. The possible measurement error increases with minimal (around0.5%).  