PCB-339A31/NC
basic data | |||
sensitivity (±10%) | 10 mV / g | 1.02 mV/(m/s²) | |
range | ±500 g pk | ±4. 905 m/s 2 pk | |
frequency range (±5%) | 2 … 6,000 Hz | ||
Frequency range (± 10%) | 1 … 8,000 Hz | ||
resonance frequency | ≥ 25,000 Hz | ||
type of filter | low pass first-order | ||
edge steepness of the filter | 6 dB/octave | ||
electric filter corner frequency | > 13,000 Hz | ||
Wide band resolution | 0.008 g RMS | 0.078 m/s² RMS | [1] |
Linearity | ≤ 0.5% | ||
transverse acceleration sensitivity | ≤ 5% | ||
conditions | |||
Overload limit (shock) | ±5. 000g pk | ±49. 050 m/s² pk | |
temperature range (operation) | -65 … 325 ° F | -54 … 163 ° C | |
Temperature coefficient of sensitivity | ≤0,011 %/°F | ≤ 0.020 %/°C | |
technical | |||
Supply voltage | 18 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤200Ω | ||
Bias voltage (at room temperature) | 7 … 11 V DC | ||
Discharging charging time constant | 0.6 … 2 s | ||
settlingbr(auf Bias-Spannung ±10 %) | < 3 s | ||
Spectral noise (1 Hz) | 1,700 µg / √ Hz | 16,660 (µm / s ²) / √ Hz | [1] |
spectral noise (10 Hz) | 500 µg / √ Hz | 4,900 ( µm / s ²) / √ Hz | [1] |
Spectral noise (100 Hz) | 200 µg / √ Hz | 1.960 (µm / s ²) / √ Hz | [1] |
spectral noise (1,000 Hz) | 100 µg / √ Hz | 980 (µm / s ²) / √ Hz | [1] |
physical properties | |||
geometry of the sensor element | shear principle | ||
housing material | titanium | ||
Sealing | hermetically sealed | ||
size - height | 0.55 in | 14 mm | |
Size - length | 0.4 in | 10.2 mm | |
Size - width | 0.4 in | 10.2 mm | |
mass | 0.2 oz | 5.5 grams | [1] |
electric Connection | 8-36 4-Pin | ||
connection position | side | ||
fixing | mounting bolt | ||
Mounting screw | 5-40 female | ||
notes | |||
[1] | typically | ||
[2] | details:see PCBs Declaration of conformance PS023 | ||
Accessories | |||
080A | adhesive mounting | -1 | |
080A109 | mounting wax | -1 | |
080A90 | CA | -1 | |
081A27 | mounting bolts, 5-40 on 5-40 | -1 | |
081A90 | mounting bolts, 10-32 on 5-40 | -1 | |
ACS-1T | Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency | -1 | |
ACS-44T | extended frequency response, top 5% frequency up to top 10% frequency (additional calibration for ACS-1 T) | -1 | |
M081A27 | metric Mounting bolts, 5-40 M3 x 0.50 | -1 | |
information | |||
temperature range | -54 … 163 ° C | ||
Features | very low temperature coefficient |