PCB-(M)124A24
    zoom_out_map

      PCB-(M)124A24

    • ICP® pressure sensor with INVAR-membrane,
    • For rocket engines,
    • Water cooled,
    • Measuring range 6,900 kPa,
    • Sensitivity 0.72 mV / kPa,
    • 10-32 female connector
    • of<t? 100 M??

      basic data
      measuring range (±5 V output range)1,000 psi6.895 kPa 
       
      usable range (output range ±10 V)2,000 psi13.790 kPa 
       
      sensitivity (±15%)5.0 mV / psi0,725 mV / kPa 
       
      maximum static pressure5,000 psi34.475 kPa 
       
      Resolution0,02 psi0.14 kPa 
       
      resonance frequency≥ 15,000 Hz  
       
      rise time (reflected pressure)≤ 30 µs  
       
      lower limiting frequency (-5%)0.005 Hz  
       
      linearity≤1.0% FS [1]
      conditions
      acceleration sensitivity≤ 0.002 psi/g≤ 0,0014 kPa/(m/s²) 
       
      temperature range (operation)-100 … 250 ° F-73 … 121 ° C[2]
       
      Temperature coefficient of sensitivity≤ 0.03 %/°F≤ 0,054 %/°C 
       
      Maximum shock (ffor fraction of a second)5,000 ° F2,760 ° C 
       
      maximum shock resistance10.000 g pk98.070 m/s² PK 
      Technical features
      output polarity (positive pressure)positive  
       
      discharging charging time constant (at room temperature)≤100 Ω  
       
      Supply20 … 30 V DC  
       
      constant power supply2 … 20 mA  
       
      output impedance≤100 Ω  
       
      Bias voltage8 … 14 V DC  
       
      Electrical insulation≤100 Ω 
      physical properties
      geometry of the sensor elementcompression principle  
       
      Sensor elementquartz  
       
      housing materialstainless steel  
       
      membraneINVAR  
       
      sealinghermetically sealed welded  
       
      electrical connection10-32-coaxial socket  
       
      Weight3.9 oz110 g 
       
      cord typetype 006, robust low-noise cable  
       
      cable length4 ft1.2 m 
       
      Water flow rate (at 50 psi)1.2 gal / min4.5 l/min 
      notes
      [1]zero-based balancing line, determined with the Method of least squares  
       
      [2]specification refers to the operating temperature of the internal sensor without cooling.  
       
      [3]details: see PCBs Declaration of conformance PS023  
      equipment
      065A09gasket, 0,560 ' au need x 0.500 "x 0,060" high brass3 
       
      070A08cable adapter (10-32-female to BNC female)-1 
      (M) metric mounting
      Accessories supplied   
       
      065A16gasket, 0,624 "outside x 0,553" x 0,060 "high brass3 
      (S) stainless steel diaphragm
      membrane316 L ( Stainless steel)  
      PCB-(M)124A24

      Specific References

      Download

      124A24_drawing.PDF

      Technical drawing

      Download (47.03k)

      124A24_manual.PDF

      Operating instructions

      Download (203.37k)

      124A24_specs.PDF

      Technical data sheet

      Download (48.92k)