PCB-(M)103B02
basic data | |||
measuring range | 3.00 psi | 180.3 dB | |
usable range | 6.00 psi | 186.3 dB | [1] |
Sensitivity (±15%) | 1,500 mV / psi | 217.5 mV / kPa | |
maximum pressure | 250 psi | 1.724 kPa | |
resolution | psi 0.00002 | 77 dB | |
resonance frequency | ≥ 13,000 Hz | ||
rise time | ≤ 25 µs | ||
Lower limiting frequency (-5%) | 5 Hz | ||
linearity | ≤2.0% FS | [2] | |
conditions | |||
Acceleration sensitivity | ? 0.0005 psi/g | ? 0.0035 kPa/(m/s²) | |
temperature range (operation) | -100 … 250 ° F | -73 … 121 ° C | |
Temperature coefficient of sensitivity | ≤0,2 %/°F | ≤0.06 %/°C | |
maximum shock (for fraction of a second) | 1,000 ° F | 538 ° C | |
Maximum shock resistance | 1,000 g pk | 9.807 m/s² pk | |
Technical properties | |||
discharge charge time constant (at room temperature) | ? 0,1 s | ||
supply | 20 … 30 V DC | ||
Constant power supply | 2 … 20 mA | ||
output impedance | ≤100 Ω | ||
Bias voltage | 7 … 13 V DC | ||
Physical properties | |||
sensor element | ceramic | ||
housing material | stainless steel | ||
Diaphragm | 316 L (stainless steel) | ||
sealing | hermetically sealed welded | ||
wiring | 10-32 -. Coaxial socket | ||
mass | 0.11 oz | 3.15 grams | |
notes | |||
[1] | for output rangeup to 10 V, the supply voltage must be at least 24 V DC. At low bias voltage of the sensor, no negative output range is usable up to-10 V. | ||
[2] | zero-based balancing line, determined using the method of least squares | ||
equipment | |||
060A10 | Mounting sleeve, 1/2 "-20-2A thread, 7/16" hex | -1 | |
065A66 | adhesive mounting ring | -3 | |
160-0.242-00 | O-ring | -. 3 | |
(M) metric mounting | |||
equipment | |||
060A24 | installation sleeve, M14 x 1.25-6 G-thread, 11 mm hexagonal material: 17-4 (Stainless steel) | -1 |