PCB-356A36
- Triaxial ICP® miniature vibration sensor, li >
- Measuring range 500 g
- Sensitivity 10 mV / g,.
- Frequency range 1... 4,000 Hz,
- Dimensions 4.3 grams.
- 4-pin female connector on the side
Basic data | |||
Sensitivity (±10 %) | 10 mV / g | 1.02 mV/(m/s²) | |
Measuring range | ±500 gPK | ±4.905 m/s²PK | |
Frequency range (≤5 %) | 1... 4,000 Hz | ||
Resonance frequency | ≥70.000 Hz | ||
Wide band resolution | 0.002 g RMS | 0.02 m/s² RMS | [3] |
Linearity error | ≤1 % | [1] | |
Transverse acceleration sensitivity | ≤5 % | ||
Conditions of use | |||
Overload limit (shock) | ±5.000 gPK | ±49.050 m/s²PK | |
Temperature range (operation) | -65... 250 ° F | -54... 121 ° C | |
Technical properties | |||
Supply voltage | 23... 30 V DC | [2] | |
constant power supply | 2... 20 mA | ||
output impedance | 100 Ω | ||
Bias voltage | 7... 16 V DC | [4] | |
discharging charging time constant | 0,4 … 1,5 s | ||
settling time (auf Bias-Spannung ±10 %) | <5 s | ||
spectral noise (1 Hz) | 1,000 µg/√Hz | 9,180 (µm/s²)/√Hz | [3] |
spectral noise (10 Hz) | 1,962 (µm/s²)/√Hz | [3] | |
spectral noise (100 Hz) | 50 µg/√Hz | 491 (µm/s²)/√Hz | [3] |
Spectral noise (1,000 Hz) | 25 µg/√Hz | 245,3 (µm/s²)/√Hz | [3] |
physical properties | |||
sensor element | ceramic | ||
Geometry of the sensor element | shear principle | ||
Housing material | Titanium | ||
Sealing | Hermetic | ||
Size - height | 0.45 in | 11.4 mm | |
Size - length | 0.82 in | 20.8 mm | |
Size - width | 0.45 in | 11.4 mm | |
Weight (without cable) | 0.15 oz | 4.3 grams | [3] |
Electrical connection | 1/4 "-28 4-pin | ||
Connecting position | On the side | ||
Fixing | Adhesive mounting | ||
Notes | |||
[1] | Zero-balance just, determined using the method of least squares | ||
[2] | The full range can be used only when a sufficiently high voltage. | ||
[3] | Typically | ||
[4] | The TEDS option increases the bias voltage by 1V. | ||
[5] | Details: see PCBs Declaration of conformance PS023 | ||
Included accessories | |||
080A109 | Mount wax | -1 | |
ACS-1T | Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5%-Frequenz | -1 | |
(HT) High temperature electronics | |||
Frequency range (≤5 %) | 4... 4,000 Hz | ||
Temperature range | -65... 325 ° F | -54... 163 ° C | |
Discharge charge time constant | 0.1... 0.6 s | ||
(T) TEDS memory in accordance with IEEE PP1451. 4 | |||
(TLA) TEDS LMS International - free format | |||
(TLB) TEDS LMS international - format for the automotive industry | |||
(TLC) TEDS LMS international - format for the aviation industry | |||