PCB-356A13/NC
    zoom_out_map

      PCB-356A13/NC

      • Triaxial ICP® miniature vibration sensor,
      • Mass 1 gram,
      • Measuring range 1000 g,
      • Sensitivity 5 mV / g,
      • Frequency range 2 … 8,000 Hz,
      • Integrated light connection cable, length 1.5 m, ending on 4-pin female connector,
      • without extension cable

      basic data
      Sensitivity (± 20%)5 mV / g0.51 mV / (m / s)
      measuring range± 1.000 g pk± 9,810 m / s² pk
      Frequency range (Y- and Z-axis) 
      (± 5%)
      2 ... 8000 Hz
      Frequency range (X-axis) (± 5%)2 ... 5000 Hz
      Frequency range (X-axis) (+1 dB)≥8.000 Hz
      resonant frequency≥50.000 Hz
      Broadband resolution0.003 g RMS0.03 m / s RMS[3]
      linearity error≤1%[2]
      Lateral acceleration sensitivity≤5%
      Operating conditions
      Overload limit (shock)± 10,000 g pk± 98,100 m / s²pk
      The temperature range (operation)-65 ... 250 ° F-54 ... 121 ° C[4]
      Technical characteristics
      supply voltage18 ... 30 V DC
      Constant current supply2 ... 20 mA
      output impedance≤200 Ω
      Bias voltage7 ... 11 V DC
      discharging0.24 ... 1.0 s
      Settling time 
      (on the bias voltage ± 10%)
      <3 s
      Spectral Noise (1 Hz)1200 µg/√Hz11,772 (µm/s²)/√Hz[3]
      Spectral noise (10 Hz)300 µg/√Hz2,943 (µm/s²)/√Hz[3]
      Spectral noise (100 Hz)100 µg/√Hz981 (µm/s²)/√Hz[3]
      Spectral noise (1,000 Hz)30 µg/√Hz294 (µm/s²)/√Hz[3]
      physical properties
      sensor elementceramics
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealhermetically sealed
      Size - Height0.25 in6.35mm
      Size - Length0.375 in9.53mm
      Size - Width0.25 in6.35mm
      Weight (without cable)0.04 oz1.0 grams[3]
      electrical connectionintegrated cable
      cable outletLaterally
      cable termination1/4 "-28 4-pin socket
      cable length5 ft1.5 m[1]
      cable typeType 099, four twisted wires
      attachmentadhesive mounting
      Hints
      [1]So that the noise levels do not exceed the specifications due to electromagnetic interference and crosstalk, the length of the integrated cable must not exceed 1.5 meters.
      [2]Zero-based line of best fit, determined by the method of least squares
      [3]typically,
      [4]The data for temperatures above 121 ° C only apply to transducers with HT option.
      included supply
      080A109mounting wax-1
      080A90superglue-1
      ACS-1TFrequency response for triaxial receiver, traceable to NIST, 10 Hz up to the top 5% -frequency-1
      (HT) High temperature electronics
      temperature range-65 ... 325 ° F-54 ... 163 ° C
      PCB-356A13/NC

      Specific References

      Download

      356A13_drawing.PDF

      Technical drawing

      Download (478.44k)

      356A13_specs.PDF

      Technical data sheet

      Download (32.38k)

      356A13_NC_manual.PDF

      Operating instructions

      Download (2.06M)