PCB-356A13/NC
- Triaxial ICP® miniature vibration sensor,
- Mass 1 gram,
- Measuring range 1000 g,
- Sensitivity 5 mV / g,
- Frequency range 2 … 8,000 Hz,
- Integrated light connection cable, length 1.5 m, ending on 4-pin female connector,
- without extension cable
basic data | |||
Sensitivity (± 20%) | 5 mV / g | 0.51 mV / (m / s) | |
measuring range | ± 1.000 g pk | ± 9,810 m / s² pk | |
Frequency range (Y- and Z-axis) (± 5%) | 2 ... 8000 Hz | ||
Frequency range (X-axis) (± 5%) | 2 ... 5000 Hz | ||
Frequency range (X-axis) (+1 dB) | ≥8.000 Hz | ||
resonant frequency | ≥50.000 Hz | ||
Broadband resolution | 0.003 g RMS | 0.03 m / s RMS | [3] |
linearity error | ≤1% | [2] | |
Lateral acceleration sensitivity | ≤5% | ||
Operating conditions | |||
Overload limit (shock) | ± 10,000 g pk | ± 98,100 m / s²pk | |
The temperature range (operation) | -65 ... 250 ° F | -54 ... 121 ° C | [4] |
Technical characteristics | |||
supply voltage | 18 ... 30 V DC | ||
Constant current supply | 2 ... 20 mA | ||
output impedance | ≤200 Ω | ||
Bias voltage | 7 ... 11 V DC | ||
discharging | 0.24 ... 1.0 s | ||
Settling time (on the bias voltage ± 10%) | <3 s | ||
Spectral Noise (1 Hz) | 1200 µg/√Hz | 11,772 (µm/s²)/√Hz | [3] |
Spectral noise (10 Hz) | 300 µg/√Hz | 2,943 (µm/s²)/√Hz | [3] |
Spectral noise (100 Hz) | 100 µg/√Hz | 981 (µm/s²)/√Hz | [3] |
Spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm/s²)/√Hz | [3] |
physical properties | |||
sensor element | ceramics | ||
Geometry of the sensor element | shear principle | ||
housing material | titanium | ||
seal | hermetically sealed | ||
Size - Height | 0.25 in | 6.35mm | |
Size - Length | 0.375 in | 9.53mm | |
Size - Width | 0.25 in | 6.35mm | |
Weight (without cable) | 0.04 oz | 1.0 grams | [3] |
electrical connection | integrated cable | ||
cable outlet | Laterally | ||
cable termination | 1/4 "-28 4-pin socket | ||
cable length | 5 ft | 1.5 m | [1] |
cable type | Type 099, four twisted wires | ||
attachment | adhesive mounting | ||
Hints | |||
[1] | So that the noise levels do not exceed the specifications due to electromagnetic interference and crosstalk, the length of the integrated cable must not exceed 1.5 meters. | ||
[2] | Zero-based line of best fit, determined by the method of least squares | ||
[3] | typically, | ||
[4] | The data for temperatures above 121 ° C only apply to transducers with HT option. | ||
included supply | |||
080A109 | mounting wax | -1 | |
080A90 | superglue | -1 | |
ACS-1T | Frequency response for triaxial receiver, traceable to NIST, 10 Hz up to the top 5% -frequency | -1 | |
(HT) High temperature electronics | |||
temperature range | -65 ... 325 ° F | -54 ... 163 ° C |