PCB-356A13
- Triaxial ICP® miniature vibration sensor, li >
- Mass 1 gram,.
- Measuring range 1000 g,
- Sensitivity 5 mV / g,.
- Frequency range 2... 8,000 Hz,
- Integrated light connection cable, length 1.5 m,
ending on 4-pin female connector. - Including extension cable, length 1.5 m,
ending on three BNC plugs
| Basic data | |||
| Sensitivity (±20 %) | 5 mV / g | 0.51 mV/(m/s²) | |
| Measuring range | ±1.000 gPK | ±9.810 m/s²PK | |
| Frequency range (Y - and Z-axis) (≤5 %) | 2... 8,000 Hz | ||
| Frequency range (X-axis) (≤5 %) | 2... 5,000 Hz | ||
| Frequency range (X-axis) (+ 1 dB) | ≤8. 000 Hz | ||
| Resonance frequency | ≥50.000 Hz | ||
| Wide band resolution | 0.003 g RMS | 0.03 m/s² RMS | [3] |
| Linearity error | ±1 % | [2] | |
| Transverse acceleration sensitivity | ≤5 % | ||
| Conditions of use | |||
| Overload limit (shock) | ±10.000 gPK | ±98.100 m/s²PK | |
| temperature range (operation) | -65... 250 ° F | -54... 121 ° C | [4] |
| specifications | |||
| power supply | 18... 30 V DC | ||
| constant power supply | 2... 20 mA | ||
| output impedance | ≤200Ω | ||
| Bias voltage | 7... 11 V DC | ||
| discharging charging time constant | 0.24...1.0 s | ||
| settling time (auf Bias-Spannung ±10 %) | < 3s | ||
| spectral noise (1 Hz) | 1.200 µg/√Hz | 11.772 (µm/s²)/√Hz | [3] |
| spectral noise (10 Hz) | 300 µg/√Hz | 2.943 (µm/s²)/√Hz | [3] |
| spectral noise (100 Hz) | 100 µg/√Hz | 981 (µm/s²)/√Hz | [3 ] |
| Spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm/s²)/√Hz | [3] |
| Physical properties | |||
| Sensor element | Ceramic | ||
| Geometry of the sensor element | Shear principle | ||
| Housing material | Titanium | ||
| Sealing | Hermetic | ||
| Size - height | 0.25 in | 6.35 mm | |
| Size - length | 0,375 in | 9.53 mm | |
| Size - width | 0.25 in | 6.35 mm | |
| Weight (without cable) | 0.04 oz | 1.0 grams | [3] |
| Electrical connection | Integrated cable | ||
| Cable outlet | On the side | ||
| Cable termination | 1/4 "-28 4-pin connector | ||
| Cable length | 5 ft | 1.5 m | [1] |
| Cable type | Type 099, four twisted wires | ||
| Mountfree | Adhesive mounting | ||
| Notes | |||
| [1] | So the noise levels exceed the specifications not due to electromagnetic interference and cross-talk, the integrated cable length must not exceed maximum 1.5 metres. | ||
| [2] | Zero-balance just, determined using the method of least squares | ||
| [3] | Typically | ||
| [4] | The data for temperatures above 121 ° C applies only for transducers with HT option. | ||
| Included accessories | |||
| 034 G 05 | 4-wire shielded cables, 1.5 meter, 4-pin connector to three BNC | -1 | |
| 080A109 | Mount wax | -1 | |
| 080A90 | Superglue | -1 | |
| ACS-1T | Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5%-Frequenz | -1 | |
| (HT) High temperature electronics | |||
| Temperature range | 65... 325 ° F | -54... 163 ° C |