| basic data | |||
| sensitivity (±15%) | 10 mV / g | 1.02 mV/(m/s²) | |
| range | ±500 g pk | ±4. 905 m/s 2 pk | |
| frequency range (±5%) | 2 … 8,000 Hz | ||
| Resonance frequency | ≥40,000 Hz | ||
| Wide band resolution | 0.003 g RMS | 0.03 m/s² RMS | [2] |
| Linearity error | ≤1% | [3] | |
| transverse acceleration sensitivity | ≤5% | ||
| conditions | |||
| (shock) overload limit | ± 10.000 g PK | ±98.100 m/s² pk | |
| Temperature range | -65 … 250 ° F | -54 … 121 ° C | [1] |
| specifications | |||
| power supply | 18 … 30 V DC | ||
| Constant power supply | 2 … 20 mA | ||
| output impedance | ≤200Ω | ||
| Bias voltage | 7 … 11 V DC | ||
| Discharging charging time constant | 0.3 … 1,0 s | ||
| settlingbr(auf Bias-Spannung ±10 %) | < 3 s | ||
| Spectral noise (1 Hz) | 1,000 µg / √Hz | 9.810 (µm / s ²) / √Hz | [2] |
| spectral noise (10 Hz) | 300 µg / √Hz | 2.943 ( µm / s ²) / √ Hz | [2] |
| spectral noise (100 Hz) | 80 µg / √Hz | 785 (µm / s ²) / √Hz | [2] |
| spectral noise ( 1,000 Hz) | 25 µg / √Hz | 308 (µm / s ²) / √Hz | [2] |
| electrical insulation | |||
| physical properties | |||
| Sensor element | ceramic | ||
| geometry of the sensor element | shear principle | ||
| Housing material | titanium | ||
| sealing | hermetically sealed | ||
| size - H öhe | 0.30 in | 7.6 mm | |
| size - length | 0.55 in | 14.0 mm | |
| size - width | 0.55 in | 14.0 mm | |
| Dimensions (without cable) | 0.18 oz | 5.0 grams | [2] |
| wiring | 1/4 "-28 4-pin | ||
| Cable outlet | On the side | ||
| Cable length | 5 ft | 1.5 m | |
| cord type | type 034, 4-wire shielded cable | ||
| Fixing | hole | ||
| notes | |||
| [1] | the data for temperatures above 121 ° C applies only for transducers with HT option. | ||
| [2] | typically | ||
| [3] | zero-based balancing line, determined using the method of least squares | ||
| [4] | Details: see PCBs Declaration of conformance PS023 | ||
| Equipment | |||
| 039A21 | Allen wrench 3/32 "hex | -1 | |
| 081 B 93 | insulated mounting screw, 5-40 Thread x 12.7 mm long (for model 354C 10) | -1 | |
| ACS-1 T | frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the top 5% frequency | -1 | |
| (M) metric mounting | |||
| equipment | |||
| M039A22 | Allen wrench for use with M3-thread | -1 | |
| M081B93 | metric mounting screw | -1 | |
| (HT) high temperature electronics | |||
| temperature range | -65 … 325 ° F | -54 … 163 ° C |