PCB-356B10/NC
    zoom_out_map

      PCB-356B10/NC

    • Triaxial ICP® miniature vibration sensor,
    • Measuring range 5,000 g,
    • Sensitivity 1 mV / g,
    • Frequency range 2 … 7,000 Hz,
    • Weight 4 grams,
    • Integrated connection cable, length 1.5 m,
      ending on 4-pin female connector,
    • without extension cable
    • basic data
      sensitivity (±20%)1.0 mV / g0.1 mV/(m/s²)
      range±5. 000 g PK±49. 050 m/s² pk
      frequency (Y - and Z-axis) < br(≤5 %)2 … 10,000 Hz
      Frequency range (X-axis) (±5%)2 … 7,000 Hz[3] [3]
      resonance frequency≥ 55,000 Hz
      Wide band resolution0.03 g RMS0.29 m/s² RMS[2]
      Linearity≤ 2.5%[1]
      transverse acceleration sensitivity≤ 5%
      conditions of use
      Overload limit (shock)±7. 000 g pk±68. 600 m/s² pk
      temperature range (operation)-65 … 250 ° F-54 …121 ° C
      specifications
      power supply18 … 30 V DC
      Constant power supply2 … 20 mA
      output impedance≤200Ω
      Bias voltage7 … 11 V DC
      Discharging charging time constant2.5 … 4<5 s
      settling time < br(auf Bias-Spannung ±10 %)>12s
      Spectral noise (1 Hz)9,000 µg / √ Hz88.290 (µm / s ²) / √ Hz[2]
      spectral noise (10 Hz)2,500 µg / √ Hz 24.525 (µm / s ²) / √ Hz[2]
      spectral noise (100 Hz)800 µg / √ Hz7.848 (µm / s ²) / √ Hz[2]
      spectral Noise (1,000 Hz)250 µg / √ Hz2,453 (µm / s ²) / √ Hz[2]
      physical properties
      sensor elementceramic
      Geometry of the sensor elementshear principle
      housing materialtitanium
      sealedsealed close
      size - height0.4 in10.2 mm
      size - length0.4 in10.2 mm
      Size - width0.4 in10.2 mm
      dimensions (without cable)0.14 oz4 grams[2]
      electrical connectionIntegrated cable
      Cable exitside
      cable termination1/4 "-28 4-pin socket
      Kabell" änge5 ft1.5 m
      cord typetype 034, 4-wire shielded cable
      mounting screw5-40 female
      Assembly torque4 … 5 in-lb45 … 56 NCM
      notes
      [1]zero-based balancing line, determined using the method of least squares
      [2]typically
      [3]the frequency response of the X-axis is limited because the installation method.
      [4]the data for temperatures above 121 ° C applies only for transducers with HT option.
      [5]details: see PCBs Declaration of conformance PS023
      equipment
      080A Adhesive mounting-1
      080A109mounting wax-1
      081A27mounting bolts. 5-40 on 5-40-1
      081A90mounting bolts, 10-32 on 5-40-1
      ACS-1 Tfrequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency-1
      M081A27metric mounting bolts, 5-40 M3 x 0.50-1
      (HT) High temperature electronics
      temperature range-65 … 325 ° F-54 … 163 ° C