PCB-356A24/NC
zoom_out_map

PCB-356A24/NC

  • Triaxial ICP® miniature vibration sensor,
  • Measuring range 500 g
  • Sensitivity 10 mV / g,
  • Frequency range 1 … 9,000 Hz (up to 12,000 Hz ±10%),
  • mass 3.1 grams,
  • 4-pin mini connector side,
  • without connection cable
  • basic data
    sensitivity (±15%) 10 mV / g 1.02 mV/(m/s²)
    range ±500 g pk ±4. 905 m/s 2 pk
    frequency range (±5%) 1 … 9,000 Hz
    Frequency range (± 10%) 0.5 … 12,000 Hz
    resonance frequency ≥ 45,000 Hz
    wide band resolution 0,004 g RMS 0.04 m/s² RMS [1]
    Linearity ≤ 1% [3]
    transverse acceleration sensitivity ≤ 5%
    conditions of use
    (Shock) overload limit ± 10.000 g pk ±98.100 m/s² pk
    Temperature range (operation) -65 … 250 ° F -54 … 121 ° C [2]
    Technical properties
    Supply voltage 18 … 30 V DC
    Constant power supply 2 … 20 mA
    output impedance ≤200Ω
    Bias voltage 7 … 11 V DC
    discharging charging time constant 1.0 … 3<5 s
    settling time
    (on Bias-Spannung ±10%)
    < 10 s
    spectral noise (1 Hz) 900 µg / √ Hz 8.820 (µm / s ²) / √ Hz [1]
    Spectral noise (10 Hz) 250 µg / √ Hz 2,450 (µm / s ²) / √ Hz [1]
    spectral noise (100 Hz) 100 µg / √ Hz 981 (µm / s ²) / √ Hz [1]
    spectral noise (1,000 Hz) 50 µg / √ Hz 490 (µm / s ²) / √ Hz [1]
    physical properties
    sensor element Ceramic
    Geometry of the sensor element shear principle
    housing material titanium
    Sealing sealedclose
    size - height 0.28 in 7.0 mm
    size - length 0.47 in 12.0 mm
    Size - width 0.47 in 12.0 mm
    dimensions (without cable) 0.11 oz 3.1 g [1]
    electrical connection 8-36 4-Pin
    connection position side
    attachment bonding
    notes
    [1] typically
    [2] the data for temperatures above 121 ° C applies only for transducers with HT option.
    [3] zero-based balancing line, determined using the method of least squares
    [4] details: see PCBs Declaration of conformance PS023
    equipment
    080A109 mounting wax -1
    080A90 Superglue -1
    ACS-1T frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency -1
    (HT) High temperature electronics
    temperature range -65 … 325 ° F -54 … 163 ° C
    (J) mass insulation of
    electrical insulation 100,000,000 Ω
    Size - height 0.33 in x 8.3 mm
    size - length 0.47 in 12.0 mm
    Size - width 0.47 in 12.0 mm
    weight 0.13 oz 3.7 grams
    PCB-356A24/NC

    Specific References

    Download

    356A24_NC_manual.PDF

    Operating instructions

    Download (1.64M)

    356A24_drawing.PDF

    Technical drawing

    Download (47.66k)

    356A24_specs.PDF

    Technical data sheet

    Download (32.26k)