PCB-356A09
- Triaxial ICP®-Miniatur-Vibrationssensor
- Mass 1 gram
- Measuring range 1,000 g
- Sensitivity 5mV/g
- Frequency range 2 … 8,000 Hz
- 4-pin connector socket
- Including cable (034K10), length 3 meters, ending in three BNC connectors
| specifications | |||
|---|---|---|---|
| basic data | English units | SI units | |
| Sensitivity (±20%) | 10 mV/g | 1,02 mV/(m/s²) | |
| measuring range | ± 500 g pk | ±4905 m/s²pk | |
| Frequency range (Y and Z axis) (±5%) | 2 … 8.000 Hz | ||
| Frequency Response (X-Axis) (±5%) | 2 … 5.000 Hz | ||
| Frequency Response (X-Axis) (+1 dB) | ≥8.000 Hz | ||
| resonant frequency | ≥50.000 Hz | ||
| broadband resolution | 0,003 gRMS | 0,03 m/s²RMS | [2] |
| Linearitätsfehler | ≤1 % | [1] | |
| lateral acceleration sensitivity | ≤5 % | ||
| conditions of use | |||
| Overload limit (shock) | ± 5000 g pk | ±49050 m/s²pk | |
| Temperature range (operation) | -65 … 250 °F | -54 … 121 °C | [3] |
| Technical characteristics | |||
| supply voltage | 18 … 30 VDC | ||
| constant current supply | 2 … 20 mA | ||
| output impedance | ≤200 Ω | ||
| bias voltage | 7 … 12 VDC | ||
| discharge time constant | 0,24 … 1,0 s | ||
| Settling time (to bias voltage ±10%) | <3 s | ||
| Spectral noise (1 Hz) | 1.200 µg/√Hz | 11,772 (µm/s²)/√Hz | [2] |
| Spectral noise (10 Hz) | 300 µg/√Hz | 2.943 (µm/s²)/√Hz | [2] |
| Spectral Noise (100 Hz) | 100 µg/√Hz | 981 (µm/s²)/√Hz | [2] |
| Spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm/s²)/√Hz | [2] |
| physical characteristics | |||
| sensor element | pottery | ||
| Geometry of the sensor element | sharprinzip | ||
| housing material | Titan | ||
| seal | Hermetically sealed | ||
| size - height | 0,25 in | 6,35 mm | |
| size - length | 0,25 in | 6,35 mm | |
| Mass | 0,04 oz | 1.0 grams | [2] |
| Electrical connection | 8-36 4-Pin | ||
| Cable outlet | Laterally | ||
| attachment | adhesive mounting | ||
| Hints | |||
|---|---|---|---|
| [1] | Zero-based regression line, determined using the least squares method | ||
| [2] | Typically | ||
| [3] | The data for temperatures above 121 °C applies only to transducers with the HT option. | ||
| [4] | Details: siehe PCB Declaration of Conformance PS023 | ||