PCB-356A06
- Triaxialer ICP®-Miniatur-Vibrationssensor
- Mass 1 gram
- Measuring range 1,000 g
- Sensitivity 5 mV / g
- Frequency range 2 ... 8,000 Hz
- 4-pin female connector
- Including cable (034K10), length 3 meters, ending on three BNC plugs
Specifications | |||
---|---|---|---|
Basic data | English units | SI units | |
Sensitivity (± 20%) | 5 mV/g | 0,51 mV/(m/s²) | |
Measuring range | ± 1,000 g pk | ±9.810 m/s²pk | |
Frequency range (Y and Z axes) (± 5%) | 2 … 8.000 Hz | ||
Frequency range (X-axis) (± 5%) | 2 … 5.000 Hz | ||
Frequency range (X-axis) (+1 dB) | ≥8.000 Hz | ||
Resonance frequency | ≥50.000 Hz | ||
Broadband resolution | 0,003 gRMS | 0,03 m/s²RMS | [2] |
Linearitätsfehler | ≤1 % | [1] | |
Lateral acceleration sensitivity | ≤5 % | ||
Conditions of use | |||
Overload limit (shock) | ± 10,000 g pk | ±98.100 m/s²pk | |
Temperature range (operation) | -65 … 250 °F | -54 … 121 °C | [3] |
Technical characteristics | |||
Supply voltage | 18 … 30 VDC | ||
Constant current supply | 2… 20 mA | ||
Output impedance | ≤200 Ω | ||
Bias voltage | 7 … 12 VDC | ||
Discharge time constant | 0,24 … 1,0 s | ||
Settling time (to bias voltage ± 10%) | <3 s | ||
Spectral noise (1 Hz) | 1.200 µg/√Hz | 11,772 (µm / s²) / √Hz | [2] |
Spectral noise (10 Hz) | 300 µg/√Hz | 2,943 (µm / s²) / √Hz | [2] |
Spectral noise (100 Hz) | 100 µg/√Hz | 981 (µm / s²) / √Hz | [2] |
Spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm / s²) / √Hz | [2] |
Physical characteristics | |||
Sensor element | Ceramics | ||
Geometry of the sensor element | Scherprinzip | ||
Housing material | Titan | ||
seal | Hermetically sealed | ||
Size - height | 0,25 in | 6,35 mm | |
Size - length | 0,25 in | 6,35 mm | |
Size - width | 0,25 in | 6,35 mm | |
Mass | 0,04 oz | 1.0 grams | [2] |
Electrical connection | 8-36 4-Pin | ||
Cable outlet | Laterally | ||
Attachment | Adhesive mounting |
Hints | |||
---|---|---|---|
[1] | Zero-based best-fit line, determined using the least squares method | ||
[2] | Typically | ||
[3] | The data for temperatures above 121 ° C only apply to transducers with the HT option. | ||
[4] | Details: siehe PCB Declaration of Conformance PS023 |
included supply | ||
---|---|---|
034K10 | Cable 10FT Mini 4 Pin To (3) BNC | (1) |
080A109 | Assembly wax | (1) |
080A90 | Superglue | (1) |
ACS-1T | Frequency response for triaxial transducers, traceable to NIST, 10 Hz up to the upper 5% frequency | (1) |