PCB-356A06
- Triaxialer ICP®-Miniatur-Vibrationssensor
- Mass 1 gram
- Measuring range 1,000 g
- Sensitivity 5 mV / g
- Frequency range 2 ... 8,000 Hz
- 4-pin female connector
- Including cable (034K10), length 3 meters, ending on three BNC plugs
| Specifications | |||
|---|---|---|---|
| Basic data | English units | SI units | |
| Sensitivity (± 20%) | 5 mV/g | 0,51 mV/(m/s²) | |
| Measuring range | ± 1,000 g pk | ±9.810 m/s²pk | |
| Frequency range (Y and Z axes) (± 5%) | 2 … 8.000 Hz | ||
| Frequency range (X-axis) (± 5%) | 2 … 5.000 Hz | ||
| Frequency range (X-axis) (+1 dB) | ≥8.000 Hz | ||
| Resonance frequency | ≥50.000 Hz | ||
| Broadband resolution | 0,003 gRMS | 0,03 m/s²RMS | [2] |
| Linearitätsfehler | ≤1 % | [1] | |
| Lateral acceleration sensitivity | ≤5 % | ||
| Conditions of use | |||
| Overload limit (shock) | ± 10,000 g pk | ±98.100 m/s²pk | |
| Temperature range (operation) | -65 … 250 °F | -54 … 121 °C | [3] |
| Technical characteristics | |||
| Supply voltage | 18 … 30 VDC | ||
| Constant current supply | 2… 20 mA | ||
| Output impedance | ≤200 Ω | ||
| Bias voltage | 7 … 12 VDC | ||
| Discharge time constant | 0,24 … 1,0 s | ||
| Settling time (to bias voltage ± 10%) | <3 s | ||
| Spectral noise (1 Hz) | 1.200 µg/√Hz | 11,772 (µm / s²) / √Hz | [2] |
| Spectral noise (10 Hz) | 300 µg/√Hz | 2,943 (µm / s²) / √Hz | [2] |
| Spectral noise (100 Hz) | 100 µg/√Hz | 981 (µm / s²) / √Hz | [2] |
| Spectral noise (1,000 Hz) | 30 µg/√Hz | 294 (µm / s²) / √Hz | [2] |
| Physical characteristics | |||
| Sensor element | Ceramics | ||
| Geometry of the sensor element | Scherprinzip | ||
| Housing material | Titan | ||
| seal | Hermetically sealed | ||
| Size - height | 0,25 in | 6,35 mm | |
| Size - length | 0,25 in | 6,35 mm | |
| Size - width | 0,25 in | 6,35 mm | |
| Mass | 0,04 oz | 1.0 grams | [2] |
| Electrical connection | 8-36 4-Pin | ||
| Cable outlet | Laterally | ||
| Attachment | Adhesive mounting | ||
| Hints | |||
|---|---|---|---|
| [1] | Zero-based best-fit line, determined using the least squares method | ||
| [2] | Typically | ||
| [3] | The data for temperatures above 121 ° C only apply to transducers with the HT option. | ||
| [4] | Details: siehe PCB Declaration of Conformance PS023 | ||
| included supply | ||
|---|---|---|
| 034K10 | Cable 10FT Mini 4 Pin To (3) BNC | (1) |
| 080A109 | Assembly wax | (1) |
| 080A90 | Superglue | (1) |
| ACS-1T | Frequency response for triaxial transducers, traceable to NIST, 10 Hz up to the upper 5% frequency | (1) |