PCB-356A04/NC
    zoom_out_map

      PCB-356A04/NC

      • Triaxial ICP®/IEPE miniatur vibration sensor
      • Operating temperature up to 163 ° C
      • Measuring range 5,000 g
      • Sensitivity 1 mV / g
      • Frequency range 1… 6,000 Hz
      • Integrated, highly flexible connection cable, length 1.5 meters,
      • ending on 4-pin connector
      • Without connection cable
      specifications
      basic dataEnglish unitsSI units 
      Sensitivity (± 20%)1 mV/g0,10 mV/(m/s²)
      measuring range± 5,000 g pk±49.050 m/s²pk
      Frequency range (+/- 5%)1.2 … 6.000 Hz
      Frequency range (+/- 10%)1 … 10.000 Hz
      resonant frequency≥50 kHz
      Broadband resolution0,02 gRMS0,02 m/s²RMS[1]
      Linearitätsfehler≤1 %[2]
      Lateral acceleration sensitivity≤5 %
      Operating conditions
      Overload limit (shock)± 10,000 g pk±98.100 m/s²pk
      Temperature range (operation)-65 … to +325 °F
      temperature rangeSee graph[1]
      Strain sensitivity (base area)≤0.05 g / me≤0.5 (m / s²) / me[1]
      Technical characteristics
      excitation voltage18 … 30 VDC
      Constant current supply2 ... 20 mA
      output impedance≤100 Ω
      Bias voltage8 … 12 VDC
      discharging0,4 … 1,2 s
      Settling time
      (on bias voltage ± 10%)
      <3 s
      Spectral noise (1 Hz)4.7 mg/√Hz46 mm/s²/√Hz[1]
      Spectral noise (10 Hz)1.2 mg/√Hz11.8 mm/s²/√Hz[1]
      Spectral noise (100 Hz)0.48 mg/√Hz4.71 mm/s²/√Hz[1]
      Spectral noise (1 kHz)0.17 mg/√Hz1.67 mm/s²/√Hz[1]
      Spectral noise (10 kHz)0.13 mg/√Hz1.28 mm/s²/√Hz[1]
      Physical properties
      sensor elementceramics
      Geometry of the sensor elementScherprinzip
      housing materialTitan
      sealHermetically
      Size - height0,25 in6,35 mm
      Size - length0,25 in6,35 mm
      Size - width0,25 in6,35 mm
      Mass (without cable)0,03 oz0.8 grams[1]
      Electrical connectionIntegrated cable
      KabelabgangLaterally
      cable termination1/4 4-Pin Jack
      cable length5 ft1,5 m
      cable type019 4-way shielded
      attachmentadhesive mounting

      [3]

      Hints
      [1]typically,
      [2]Zero-based best-fit line, determined using the least squares method
      [3]Details: siehe PCB Declaration of Conformance PS023

      included supply
      080A109mounting wax(1)
      080A90superglue(1)
      ACS-1TFrequency response for triaxial transducers, traceable to NIST, 10 Hz up to the upper 5% frequency(1)
      PCB-356A04/NC

      Specific References

      Download

      356A04_specs

      Download (68.74k)

      356A04_drawing

      Download (89.95k)

      356A04_manual

      Download (1.85M)