PCB-J356A44
zoom_out_map

PCB-J356A44

  • Triaxial ICP® miniature vibration sensor
  • Mass-insulated housing
  • With TEDS 1.0
  • Measuring range 100 g
  • Sensitivity 50mv / g
  • Frequency range 0.4... 10,000 Hz
  • Dimensions 4.2 grams
  • 4-pin female connector on the side

 

Specifications
Basic dataEnglish unitsSI units 
Sensitivity (±10 %) 50 mV / g 5.1 mV/(m/s²)  
Measuring range ±100 g pk ±981 m/s² pk  
Frequency range (≤5 %) 0.7... 7,000 Hz  
Frequency range (±10 %) 0.4... 10,000 Hz  
Resonance frequency ≥30.000 Hz  
Wide band resolution (1... 10,000 Hz) 0.0006 g rms 0.006 m/s² rms [1]
Linearity error ≤1 % [2]
Transverse acceleration sensitivity ≤6 %  
TEDS memory chips in accordance with
IEEE P1451. 4
Yes  
Conditions of use
Overload limit (shock) ±5.000 g pk ±49.050 m/s² pk  
Temperature range (operation) -65 … 200 °F -54... 93 ° C  
Strain sensitivity (footprint) 0.001 g/µε 0.01 (m/s²)/µε [1]
Technical characteristics
Power supply 20... 30 V DC  
Constant power supply 2... 20 mA  
Output impedance ≤200Ω  
Bias voltage 8... 12 V DC  
Discharge charge time constant 0.8... 2.4 s  
Settling time (on area within ±10% of the bias voltage)  
Spectral noise (1 Hz) 1,962 (µm/s²)/√Hz [1]
Spectral noise (10 Hz) 45 µg/√Hz 441 (µm/s²)/√Hz [1]
Spectral noise (100 Hz) 20 µg/√Hz 196 (µm/s²)/√Hz [1]
Spectral noise (1,000 Hz) 6 µg/√Hz 58.9 (µm/s²)/√Hz [1]
Electrical insulation (base) ≥100 MΩ  
Physical properties
Sensor element Ceramic  
Geometry of the sensor element Shear principle  
Housing material Titanium  
Sealing Hermetic  
Size - height 0.40 in 10.2 mm  
Size - length 0.40 in 10.2 mm  
Size - width 0.40 in 10.2 mm  
Mass 0.15 oz 4.2 grams [1]
Electrical connection 1/4 "-28 4-pin  
Connecting position On the side  
Fixing Adhesive mounting  
Notes
[1] Typically    
[2] Zero-balance just, determined using the method of least squares    
[3] Details: See PCBs Declaration of conformance PS023    
Included accessories
080A109 Mount wax (1)
080A90 Superglue (1)
ACS-1T Frequency response for Triaxial accelerometer, traceable to NIST, 10 Hz up to the upper 5% frequency (1)
PCB-J356A44

Specific References

Download

J356A44_drawing

Download (89.75k)

J356A44_specs