PCB-356A44
- Triaxial ICP® miniature vibration sensor,
- With TEDS 1.0,
- Measuring range 100 g,
- Sensitivity 50 mV / g,
- Frequency range 0.4... 10,000 Hz,
- Dimensions 4.2 grams,
- 4-pin female connector on the side,
specifications | |||
---|---|---|---|
basic data | English units | SI units | |
Sensitivity (± 10%) | 50 mV / g | 5.1 mV / (m / s) | |
measuring range | ± 100 g pk | ± 981 m / s pk | |
Frequency range (± 5%) | 0.7 ... 7000 Hz | ||
Frequency range (± 10%) | 0.4 ... 10,000 Hz | ||
resonant frequency | ≥30.000 Hz | ||
Broadband resolution (1 ... 10,000 Hz) | 0.0006 g rms | 0.006 m / s rms | [1] |
linearity error | ≤1% | [2] | |
Lateral acceleration sensitivity | ≤6% | ||
TEDS memory chip according to IEEE P1451.4 | Yes | ||
Operating conditions | |||
Overload limit (shock) | ± 5,000 g pk | ± 49 050 m / s pk | |
The temperature range (operation) | -65 ... 200 ° F | -54 ... 93 ° C | |
Strain sensitivity (base surface) | 0.001 g / µε | 0.01 (m / s²) / µε | [1] |
Technical Specifications | |||
supply voltage | 20 ... 30 V DC | ||
Constant current supply | 2 ... 20 mA | ||
output impedance | ≤200 Ω | ||
Bias voltage | 8 ... 12 V DC | ||
discharging | 0.8 ... 2.4 s | ||
Settling time (on the range within ± 10% of the bias voltage) | ≥5 s | ||
Spectral Noise (1 Hz) | 200 µg/√Hz | 1,962 (µm/s²)/√Hz | [1] |
Spectral noise (10 Hz) | 45 µg/√Hz | 441 (µm/s²)/√Hz | [1] |
Spectral noise (100 Hz) | 20 µg/√Hz | 196 (µm/s²)/√Hz | [1] |
Spectral noise (1,000 Hz) | 6 .mu.g / ?Hz | 58.9 (µm/s²)/√Hz | [1] |
physical properties | |||
sensor element | ceramics | ||
Geometry of the sensor element | shear principle | ||
housing material | titanium | ||
seal | hermetically sealed | ||
Size - Height | 0.40 in | 10.2 mm | |
Size - Length | 0.40 in | 10.2 mm | |
Size - Width | 0.40 in | 10.2 mm | |
Dimensions | 0.15 oz | 4.2 grams | [1] |
electrical connection | 1/4 "-28 4-pin | ||
port location | Laterally | ||
attachment | adhesive mounting |
Hints | |||
---|---|---|---|
[1] | typically, | ||
[2] | Zero-based line of best fit, determined by the method of least squares | ||
[3] | Details: see PCB Declaration of Conformance PS023 |
included supply | ||
---|---|---|
080A109 | mounting wax | (1) |
080A90 | superglue | (1) |
ACS-1T | Frequency response for triaxial receiver, traceable to NIST, 10 Hz up to the top 5% -frequency | (1) |