PCB-(M)221B02
zoom_out_map

PCB-(M)221B02

  • ICP® force measuring element,
  • Measuring range 445 N,
  • Sensitivity 11,2 µV / N,
  • Frequency range 0.006 … 15,000 Hz,
  • 10-32 female connector on the side
  • basic data
    sensitivity (±15%) 50 mV / lb 11.241 mV / kN
    (pressure) measuring range 100 lb 0,4448 kN
    Measuring range (traction) 100 lb 0,4448 kN
    maximum permissible static load (force) 600 lb 2,669 kN
    maximum static force (traction) 500 lb 2,224 kN
    wide band resolution 0.002 lb RMS 0,008896 N RMS [2]
    Lower limiting frequency (-5%) 0.006 Hz [1]
    upper frequency limit 15,000 Hz [4]
    linearity error ≤ 1% FS [3]
    conditions
    temperature range -65 … 250 ° F -54 … 121 ° C
    temperature coefficient Temperature coefficient of sensitivity ≤ 0.03 %/°F ≤ 0,054 %/°C
    technical properties
    discharge charge time constant (at room temperature) &ge≥120 s
    Notes
    [1] calculated on the basis of discharging charging time constant
    [2] typically
    [3] zero-based balancing line, determined using the method of least squares
    [4] suppose value determined on the basis of solid state Dynamics calculations
    [5] details: see PCBs Declaration of conformance PS023
    (M) metric mounting
    (S) negatives Output polarity
    (W) waterproof cable connection
    electrical connection sealed cable connection
    Cable exit side
    PCB-(M)221B02

    Specific References

    Download

    221B02_drawing.PDF

    Technical drawing

    Download (479.97k)

    221B02_manual.PDF

    Operating instructions

    Download (1.3M)

    221B02_specs.PDF

    Technical data sheet

    Download (67.13k)