PCB-(M)601M51
| basic data | |||
| sensitivity (±20%) | 500 mV / g | 51 mV/(m/s²) | [5] |
| measuring range | ± 10 g | ±98 m / s² | |
| Frequency range (±5%) | 17 … 240,000 cpm | 0.29 … 4,000 Hz | [2] |
| frequency range (± 10%) | 13 … 300,000 cpm | 0,21 … 5,000 Hz | |
| frequency range (± 3 dB) | 6 … 600,000 cpm | 0.1 … 10,000 Hz | |
| resonance frequency | 960 kcpm | 16,000 Hz | [4] |
| wide band resolution | 35 µg | 343 µm / s ² | [4] |
| linearity | ≤1% | [1] | |
| Transverse acceleration sensitivity | ≤ 7% | ||
| conditions of use | |||
| Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |
| temperature range | -65 … 250 ° F | -54 … 121 ° C | |
| Protection | 1.9 in | 48.3 mm | |
| weight | 2.8 oz | 80 g | |
| mounting thread | 1/4 "-28 threaded | no equivalent" | [3] |
| Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | |
| sensor element | ceramic | ||
| Geometry of the sensor element | Shear principle | ||
| Housing material | stainless steel | ||
| sealing | hermetically sealed welded | ||
| Electrical connection | 2-pin connector (MIL-C-5015) | ||
| Connection position | above | ||
| notes | |||
| [1] | zero-based balancing line, determined using the method of least squares | ||
| [2] | the upper cut-off frequency tolerance: ±10% | ||
| [3] | no equivalent in SI units | ||
| [4] | Typically | ||
| [5] | conversion factor 1 g = 9.81 m/s² | ||
| [6] | details: see PCBs Declaration of conformance PS023 | ||
| Accessories | |||
| ICS-2 | single point calibration at 100 Hz (r ückführbar on NIST) | -1 | |
| 081A40 | mounting bolts with 1/4 "-28 thread | -1 | |
| (M) metric mounting | |||
| supplied accessories" ör | |||
| M081A61 | metric mounting bolts with M6 thread | -1 |