PCB-(M)627A71
| basic data | ||||
| sensitivity (±15%) | 100 mV/g | 10.2 mV/(m/s²) | [5] | |
| measuring range | ±50 g | ±490 m / s² | ||
| Frequency range (± 3 dB) | 20 … 600,000 cpm | 0.33 … 10,000 Hz | [4] | |
| resonance frequency | 1,080 kcpm | 18,000 Hz | [3] | |
| Wide band resolution | 1,000 µg | 9,810 µm / s ² | [3] | |
| linearity | ≤1% | [1] | ||
| Transverse acceleration sensitivity | ≤ 5% | |||
| conditions of use | ||||
| Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | ||
| temperature range | -65 …200 °F | -54 … 93 ° C | ||
| Type of protection | IP64 | |||
| Technical characteristics | ||||
| settling time (on bias voltage ± 1%) | ≤ 10s | |||
| discharging charging time constant | ≥ 0<5 s | Equivalent | [2] | |
| Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | ||
| sensor element | quartz | |||
| Geometry of the sensor element | shear principle | |||
| housing material | stainless steel | |||
| sealing | hermetically sealed welded | |||
| electrical connection | terminals | |||
| connection position | above | |||
| Notes | ||||
| [1] | zero-based balancing line, determined using the method of least squares | |||
| [2] | no equivalent in SI units | |||
| [3] | typically | |||
| [4] | the upper cut-off frequency tolerance: ±10% | |||
| [5] | Conversion factor 1 g = 9.81 m/s² | |||
| [6] | details: see PCBs Declaration of conformance PS023 | |||
| equipment | ||||
| 081A40 | mounting bolts with 1 / 4 & quot;-28 thread | -1 | ||
| (M) metric mounting | ||||
| equipment | ||||
| M081A61 | metric mounting bolts with M6 threads | -1 |