PCB-(M)607A60
| basic data | |||||
| sensitivity (±15%) | 10 mV / g | 1.02 mV/(m/s²) | [6] | ||
| measuring range | ≤500 Ω | ±4. 905 m/s 2 | |||
| Frequency range (± 3 dB) | 30 … 600,000 cpm | 0.5 … 10,000 Hz | |||
| resonance frequency | 1,500 kcpm | 25,000 Hz | [1] | ||
| Wide band resolution | 350 µg | 3.434 µm / s ² | [1] | ||
| linearity | ≤1% | [3] | |||
| Lateral acceleration sensitivity | ≤ 7% | ||||
| Conditions of use | |||||
| Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |||
| Temperature range | -65 … 250 ° F | -54 … 121 ° C | |||
| protection class | IP67 | ||||
| technical characteristics | |||||
| Settling time (on bias voltage ± 1%) | ≤ 2 s | ||||
| discharging charging time constant | ≥0.3 s | ||||
| [5] | two-core cable with stainless steel reinforcement | ||||
| [6] | conversion factor 1 g = 9.81 m/s² | ||||
| [7] | Assembly requires Allen key 1/8 "(for inch mounting bolts) or 3 mm (for metric mounting bolts). | ||||
| [8] | of the mounting bolts must be tightened with a higher torque than the hex nut, so that the sensor can easily be removed. | ||||
| [9] | details: see PCBs Declaration of conformance PS023 and PS060 | ||||
| Accessories | |||||
| 080A156 | mounting bolts 1/2 "-20 1/4" 28 | -1 | |||
| ICS-2 | single point calibration at 100 Hz (traceable to NIST) | -1 | |||
| (M) metric mounting | |||||
| equipment | |||||
| M080A159A | mounting bolts 1/2 "20 M6 x 1 | -1 | |||
| (TO) temperature output | |||||
| temperature range | 36 & Emmap; 250 ° F | 2 … 121 ° C | |||
| transcription factor | 5.56 mV / ° F (zero point at 32 °F) | 10 mV / ° C | |||
| electrical connection | Integrated armoured cable | ||||
| connections (red wire) | acceleration output | ||||
| (black wire) pin assigNment | Mass | ||||
| Pin assigNment (white wire) | temperature output |