PCB-(M)603C62
| basic data | |||
| sensitivity (±10%) | 500 mV / g | 51.0 mV/(m/s²) | [6] |
| measuring range | ± 10 g | ±98 m / s² | |
| Frequency range (± 3 dB) | 30 … 180,000 cpm | 0.5 … 3,000 Hz | [5] |
| resonance frequency | 1,500 kcpm | 25,000 Hz | [2] |
| Wide band resolution | 350 µg | 3.434 µm / s ² | [2] |
| linearity | ≤1% | [3] | |
| Transverse acceleration sensitivity | ≤ 7% | ||
| conditions of use | |||
| Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |
| temperature range | -65 … 250 ° F | -54 … 121 ° C | |
| Type of protection | IP68 | ||
| Technical characteristics | |||
| settling time (on bias voltage ± 1%) | ≤ 5.0 s | ||
| discharging charging time constant | ≥ 0.3 s | ||
| Power | 18 … 28 V DC | ||
| constant power supply | 2 … 20 mA | ||
| Output impedance | < 150 Ω | ||
| Bias voltage | 8 … 12 V DC | ||
| Spectral noise (10 Hz) | 8 µg / √ Hz | 78.5 (µm / s ²) / √ Hz | [2] |
| spectral noise (100 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [2] |
| spectral noise (1,000 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [2] |
| electric Insulation (housing) | ≥ 100 MΩ | ||
| physical properties | |||
| size - Allen | 11/16 in | 18 mm | |
| size ße - height | 4.7 in | 119 mm | |
| dimensions (without cable) | 1.8 oz | 51 grams | |
| mounting thread | 1/4 "-28 threaded | " | [4] |
| [7] | details: see PCBs Declaration of conformance PS023 and PS060 | ||
| included Accessories | |||
| 081A40 | mounting bolts with 1/4 "-28 thread | -1 | |
| ICS-2 | single point calibration at 100 Hz (traceable to NIST) | -1 | " |
| (M) metric mounting | |||
| equipment | |||
| M081A61 | metric mounting bolts with M6 thread | -1 | |
| ( TO) temperature output | |||
| temperature range | 36 … 250 ° F | 2 … 121 ° C | |
| transcription factor | 5.56 mV / ° F (zero point at 32 °F) | 10 mV / ° C | |
| connections (red wire) | acceleration output | ||
| (black wire) pin assigNment | mass | ||
| Pin assigNment (white wire) | temperature output | ||
| pin assigNment (green wire) | ground | ||
| (EX) with ATEX approved | |||
| Approved for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 | ||
| approval for use in potentially explosive atmospheres | ex nL IIC T4, - 40 ° C ≤ Ta ≤ 121 ° C, II 3 G | ||
| approval for use in potentially explosive atmospheres | ex ia IIC T4,-40 ° C ≤ Ta ≤ 121 ° C, II 1 G | ||
| Approved for use in potentially explosive atmospheres | CL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I | ||
| approval for use in potentially explosive atmospheres | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 |