PCB-(M)603C62
basic data | |||
sensitivity (±10%) | 500 mV / g | 51.0 mV/(m/s²) | [6] |
measuring range | ± 10 g | ±98 m / s² | |
Frequency range (± 3 dB) | 30 … 180,000 cpm | 0.5 … 3,000 Hz | [5] |
resonance frequency | 1,500 kcpm | 25,000 Hz | [2] |
Wide band resolution | 350 µg | 3.434 µm / s ² | [2] |
linearity | ≤1% | [3] | |
Transverse acceleration sensitivity | ≤ 7% | ||
conditions of use | |||
Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |
temperature range | -65 … 250 ° F | -54 … 121 ° C | |
Type of protection | IP68 | ||
Technical characteristics | |||
settling time (on bias voltage ± 1%) | ≤ 5.0 s | ||
discharging charging time constant | ≥ 0.3 s | ||
Power | 18 … 28 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | < 150 Ω | ||
Bias voltage | 8 … 12 V DC | ||
Spectral noise (10 Hz) | 8 µg / √ Hz | 78.5 (µm / s ²) / √ Hz | [2] |
spectral noise (100 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [2] |
spectral noise (1,000 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [2] |
electric Insulation (housing) | ≥ 100 MΩ | ||
physical properties | |||
size - Allen | 11/16 in | 18 mm | |
size ße - height | 4.7 in | 119 mm | |
dimensions (without cable) | 1.8 oz | 51 grams | |
mounting thread | 1/4 "-28 threaded | " | [4] |
[7] | details: see PCBs Declaration of conformance PS023 and PS060 | ||
included Accessories | |||
081A40 | mounting bolts with 1/4 "-28 thread | -1 | |
ICS-2 | single point calibration at 100 Hz (traceable to NIST) | -1 | " |
(M) metric mounting | |||
equipment | |||
M081A61 | metric mounting bolts with M6 thread | -1 | |
( TO) temperature output | |||
temperature range | 36 … 250 ° F | 2 … 121 ° C | |
transcription factor | 5.56 mV / ° F (zero point at 32 °F) | 10 mV / ° C | |
connections (red wire) | acceleration output | ||
(black wire) pin assigNment | mass | ||
Pin assigNment (white wire) | temperature output | ||
pin assigNment (green wire) | ground | ||
(EX) with ATEX approved | |||
Approved for use in potentially explosive atmospheres | ExIA IIC T4, AExia IIC, T4 | ||
approval for use in potentially explosive atmospheres | ex nL IIC T4, - 40 ° C ≤ Ta ≤ 121 ° C, II 3 G | ||
approval for use in potentially explosive atmospheres | ex ia IIC T4,-40 ° C ≤ Ta ≤ 121 ° C, II 1 G | ||
Approved for use in potentially explosive atmospheres | CL I, div I, groups A, B, C, D CL II, div I, groups E, F, G Cl III, div I | ||
approval for use in potentially explosive atmospheres | CL I, div 2, groups A, B, C, D ExnL IIC T4, AExnA IIC T4 |