basic data | |||
sensitivity (±20%) | 500 mV / g | 51.0 mV/(m/s²) | [5] |
measuring range | ± 10 g | ±98 m / s² | |
Frequency range (± 3 dB) | 30 … 180,000 cpm | 0.5 … 3,000 Hz | [2] |
resonance frequency | 1,500 kcpm | 25,000 Hz | [1] |
Wide band resolution | 300 µg | 2,941 µm / s ² | [1] |
linearity | ≤1% | [3] | |
Transverse acceleration sensitivity | ≤ 7% | ||
conditions of use | |||
Overload limit (shock) | 5,000 g pk | 49,050 m/s² pk | |
temperature range | -65 … 250 ° F | -54 … 121 ° C | |
Type of protection | IP68 | ||
Technical characteristics | |||
settling time (on bias voltage ± 1%) | ≤ 5.0 s | ||
discharging charging time constant | ≥ 0.3 s | ||
Power | 18 … 28 V DC | ||
constant power supply | 2 … 20 mA | ||
Output impedance | < 500 Ω | ||
Bias voltage | 8 … 12 V DC | ||
Spectral noise (10 Hz) | 8 µg / √ Hz | 78.5 (µm / s ²) / √ Hz | [1] |
spectral noise (100 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [1] |
spectral noise (1,000 Hz) | 3 µg / √ Hz | 29.4 (µm / s ²) / √ Hz | [1] |
electric Insulation (housing) | ≥ 100 MΩ | ||
physical properties | |||
size - length | 3.70 in | 94,0 mm | |
Gr size - width | 0.74 at | 18.8 mm | |
size - height | 0,845 in | 21.5 mm | |
mass | 2.61 oz | 74.0 grams | |
Mounting thread | 1/4"-28 | No metric equivalent | [4] |
Assembly torque | 2 … 5 ft-lb | 2.7 … 6.8 Nm | |
sensor element | ceramic | ||
geometry of the Sensor element | shear principle | ||
housing material | stainless steel | ||
sealing | hermetically sealed welded | ||
Electrical connection | potted integrated cable | ||
cable exit | side | ||
Cable length | 10.0 ft | 3.0 m | |
Cable type | polyurethane | ||
notes | |||
[1] | typically | ||
[2] | tolerance of upper cutoff frequency: ±10% | ||
[3] | zero-based balancing line, determined using the method of least squares | ||
[4] | Mounting with M6 screw possible | ||
[5] | conversion factor 1 g = 9,81m / s² | ||
[6] | details: see PCBs Declaration of conformance PS023 | ||
equipment | |||
081A97 | Mounting screw, 1/4 "-28 x 1.00" | -1 | |
ICS-2 | single point calibration at 100 Hz (traceable to NIST) | -1 | |
(M) metric mounting | |||
Equipment | |||
M081A97 | metric mounting bolt with M6 thread | -1 |