PCB-(M)640B07
zoom_out_map

PCB-(M)640B07

  • Vibration transmitter with power output according to
    the peak value of vibration speed,
  • measuring range 0 … 25.4 mm / s,
  • output range 4 … 20 mA,
  • frequency range 1.5 … 1,000 Hz,
  • 2 Pin socket top
  • "" "
    basic data
    range 0,0 … 1 in / s pk 0.0 … 25.4 mm / s pk [1]
    Output area 4 … 20 mA
    frequency range (± 3 dB) 90 … 60,000 cpm 1.5 … 1,000 Hz [2] [3]
    Wide band resolution 0.005 in / s pk 0.13 mm / s pk [4]
    linearity error ≤1%
    conditions of use
    temperature range -40 … 185 ° F -40 … 85 ° C
    technical characteristics
    Supply voltage 12 … 30 V DC
    settling time (area within ±2% of full scale) < 30 s
    electrical insulation (housing) ≥ 100 MΩ
    physical properties
    size - hex 1.0 in 25.4 mm
    Size - height 2.6 in 66 mm
    weight 4.7 oz 131 grams
    mounting thread 1/4 "-28 UNFNo metric equivalent
    Assembly torque 3 … 5 ft-lb 4 … 7 Nm
    sensor element ceramic
    geometry the sensor element shear principle
    housing material stainless steel
    sealing hermetically sealed welded
    Electrical connection 2-pin connector (MIL-C-5015)
    connection position above
    Terminal assigNment (PIN A) Output signal 4 … 20 mA positive
    Pin assigNment (PIN B) output signal 4 … 20mA negative
    notes
    [1] conversion factor 1 in / sec = 0.0254 m/sec.
    [2] at frequencies below 5 Hz, the output signal fluctuates.
    [3] 1 Hz 60 = cpm ("Cycles Per Minute": rpm).
    [4] typically
    [5] details: see PCB Declaration of Conformance PS039 and PS053
    equipment
    081A40 mounting bolts with 1/4 "-28 thread" -1
    ICS-6 calibration of the frequency response of 10 Hz to the upper 3dB point, traceable to NIST -1
    (EX) with ATEX certificate
    Approved for use in potentially explosive atmospheres DIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4
    approval for use in potentially explosive atmospheres EEx ia IIC T4, 40 ° C ≤ Ta ≤ 80 ° C, II 1 G
    approval for use in potentially explosive atmospheres EEx nL IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 3 G
    approval for use in potentially explosive atmospheres DIV I, CL I, II, III, GRPS A-G, ExIA, AExia, IIC T4
    (M) metric mounting
    equipment
    M081A61 metric mounting bolts with M6 threaded -1
    PCB-(M)640B07

    Specific References

    Download

    640B07_drawing.PDF

    Technical drawing

    Download (190.57k)

    640B07_manual.PDF

    Operating instructions

    Download (1.99M)

    640B07_specs.PDF

    Technical data sheet

    Download (1.2M)