PCB-(M)640B07
    zoom_out_map

      PCB-(M)640B07

    • Vibration transmitter with power output according to
      the peak value of vibration speed,
    • measuring range 0 … 25.4 mm / s,
    • output range 4 … 20 mA,
    • frequency range 1.5 … 1,000 Hz,
    • 2 Pin socket top
    • """
      basic data
      range0,0 … 1 in / s pk0.0 … 25.4 mm / s pk[1]
      Output area4 … 20 mA
      frequency range (± 3 dB)90 … 60,000 cpm1.5 … 1,000 Hz[2] [3]
      Wide band resolution0.005 in / s pk0.13 mm / s pk[4]
      linearity error≤1%
      conditions of use
      temperature range-40 … 185 ° F-40 … 85 ° C
      technical characteristics
      Supply voltage12 … 30 V DC
      settling time (area within ±2% of full scale)< 30 s
      electrical insulation (housing)≥ 100 MΩ
      physical properties
      size - hex1.0 in25.4 mm
      Size - height2.6 in66 mm
      weight4.7 oz131 grams
      mounting thread1/4 "-28 UNFNo metric equivalent
      Assembly torque3 … 5 ft-lb4 … 7 Nm
      sensor elementceramic
      geometry the sensor elementshear principle
      housing materialstainless steel
      sealinghermetically sealed welded
      Electrical connection2-pin connector (MIL-C-5015)
      connection positionabove
      Terminal assigNment (PIN A)Output signal 4 … 20 mA positive
      Pin assigNment (PIN B)output signal 4 … 20mA negative
      notes
      [1]conversion factor 1 in / sec = 0.0254 m/sec.
      [2]at frequencies below 5 Hz, the output signal fluctuates.
      [3]1 Hz 60 = cpm ("Cycles Per Minute": rpm).
      [4]typically
      [5]details: see PCB Declaration of Conformance PS039 and PS053
      equipment
      081A40mounting bolts with 1/4 "-28 thread"-1
      ICS-6calibration of the frequency response of 10 Hz to the upper 3dB point, traceable to NIST-1
      (EX) with ATEX certificate
      Approved for use in potentially explosive atmospheresDIV II, CL I, GRPS A-D, ExnL, AExnA, IIC T4
      approval for use in potentially explosive atmospheresEEx ia IIC T4, 40 ° C ≤ Ta ≤ 80 ° C, II 1 G
      approval for use in potentially explosive atmospheresEEx nL IIC T4,-40 ° C ≤ Ta ≤ 80 ° C, II 3 G
      approval for use in potentially explosive atmospheresDIV I, CL I, II, III, GRPS A-G, ExIA, AExia, IIC T4
      (M) metric mounting
      equipment
      M081A61metric mounting bolts with M6 threaded-1
      PCB-(M)640B07

      Specific References

      Download

      640B07_drawing.PDF

      Technical drawing

      Download (190.57k)

      640B07_manual.PDF

      Operating instructions

      Download (1.99M)

      640B07_specs.PDF

      Technical data sheet